products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13003860308
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
glove-box
  • Acrylic Glove Box Laboratory Transparent Acrylic Vacuum Glove Box (35"x19"x20") with Optional Vacuum Flange & Gauge

    Transparent Acrylic & Plexiglass Vacuum Glove Box (35"x19"x20") with Optional Vacuum Flange & Gauge -VGB-2 1. Bench top transparent glove box offers larger inert gas environmental workspace with vacuum air  locker and side door. 2.  The glove box is made of transparent polycarbonate for clear viewing from any angle. 3.  Polycarbonate construction affords resistance to a wide range of chemicals, high-impact strength and scratch-resistance and the smooth, hemispherical interior cleans easily..

  • Small Hydraulic Press Hot Tablet Press for Glove Box with -0.1MPa Degree of Vacuum

  • Lab Glove Box Lab Double Side Single Box Four Station 800mm Extended Transition Cabin Glove Box

    Lab Double Side Single Box Four Station 800mm Extended Transition Cabin Glove Box A. Acceptance standard: Under standard conditions, that is, under constant temperature of 20-25 oC, relative humidity of 65% and inert air source of 99.999%, the oxygen index of circulating water in empty tank body is less than 0.1ppm.   B. The main technical indicators and configuration 1. Box body 1.1. Size: 1800mm (L) x 900mm (H) x 1000mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Aperture 0.3 micron 1.4. Butyl rubber gloves: original imported from the United States thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Tilted operating surface, 8mm safety tempered glass front window, wear resistance, corrosion resistance, good light transmission, 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure (-10mbar-10mbar) when used. 1.7. The cabinet is equipped with anti-reflection lighting energy-saving lamp, the light is soft. 1.8. The box body is provided with two layers of display board hoisting shelves 1.9. The box is provided with a porous power terminal board (Power supply: 220V±10% 50Hz±10%) 1.10. Three standard KF-40 ports can be configured on the housing. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters. 2. Transition cabin 2.1 Large and small transition bins (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected with glove box, adopt shaft lock large transition door, easy to operate. 2.1.2 Size: large transition cabin with diameter of 360mm and length of 800mm, piston door, transition cabin with sliding tray and polishing, a small transition cabin with size of 150mm in diameter and 300mm in length, air pumping and replenishing controlled by manual valve. 2.1.3. Tray: Freely movable extension (large overcabin configuration) 2.1.4. Vacuum ≤1bar(large and small right transition cabins are required to be vacuumed, with vacuum gauge display) 3. Control system 3.1. Mode: Including self - diagnosis, power off - start feature, with pressure control and self - adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and the transition chamber at a certain set value. a) The user can set the working pressure range between +12.5 and -12.5 mbar at will, and PLC will automatically adjust the pressure of the box within the set range. Default values for operating pressure ranges are -1 to +3 millibars. b) When the case pressure is greater than 12 mbar, PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials in the case. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of glove box, convenient operation. 4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, United States UOP purification material, Germany Baode valve. The host system is integrated with modular design, automatic electronic control air circuit solenoid valve group, PLC control, circuit, circulating pump, purification column, display integrated with an independent purifier, forming a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjusting device: Through PLC touch type adjustment (heating, pumping, purification, regeneration) the whole process except 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulating fan: 0-100m³ high speed frequency conversion fan, microprocessor controlled, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material German BASF deoxygenation material 5kg, the United States UOP highly efficient water absorption material 5kg, extremely high life, to ensure that the user in the use of the product purification capacity long lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: H13 high efficiency filter with 0.3 micron aperture screen conforming to HEPA standard. 4.9. Regeneration: used to reuse the purification system and activate it; Regeneration requires a mixture of helium /H2, nitrogen /H2, or argon /H2, with H2 accounting for 10%. 5. Display system SIEMENS, Germany, unit control using Siemens PLC touch screen. Both Chinese and English can be switched. 6. Water analyzer, (imported from abroad) brand material: British MICHELL/ (according to customer use environment decision) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's Settings to achieve circulation drop. 5) Environment: -10℃ -- 50℃ 7. Oxygen analyzer, (imported from abroad) brand materials: AVCRAY (in accordance with the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000ppm 2) Environment: -10℃ -- 50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. Regardless of gas circulation or not, the oxygen sensor can continuously detect the atmosphere in the box and display the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are accurate zero, small drift, avoid other battery materials easy to be corroded; Low replacement cost (only oxygen battery replacement). 6) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic circulation function to maintain the oxygen content in the glove compartment within the user's specified range. 8. Vacuum system Added vacuum pump start-stop time control. Edwards vacuum pump, model RV12, flow 12m3/h, limit vacuum 2x10-3 millibar. The transition chamber can be vacuumed separately and can be controlled separately at any time. (imported from abroad) 9. Box body automatic cleaning Automatic gas-controlled electroplating plate; The user sets the cleaning time, then touch the start button on the touch screen, the system will start cleaning the box, and automatically stop when the set time. 10. Organic solvent adsorption system To prevent the effect of organic solvent on the purifying column, a solvent column is connected in series to the glove box system. The medium is mainly high quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG. There are KF40 interfaces on the top and bottom of the column, which is convenient for refueling. Users can refueling by themselves. 11. Working conditions of the equipment: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory should have an independent ground wire: < 3Ω, from the equipment to the ground wire connection is recommended to use ≥10mm2 flat copper wire; 1.2. Water supply: None; 1.3. Relative humidity: < 75%; 1.4. There is no large amount of dust, corrosive, flammable and explosive gas in the room; 1.5. Equipment covers area: Length × width :3200mm× 1200mm C. Main configuration No Configuration Unit Qty Manufacturer/brand Remarks 1 Glove box Pcs 2 TMAXCN 304 stainless steel thickness 3mm 2 Transition chamber Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc Import assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, United States UOP purification material, Germany Baode valve Import assembly 5 Display system Set 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe joint Set 1 French Rocole(France) Import 8 Pressure gauge Set 2 WIka(Germany) Import 9 PLC water analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN 304 stainless steel   The partial extension of the transition module can refer to this drawing (reference only for the transition module part).      

  • Double Side Glove Box Four Station Double Box Double Side 800mm Extended Cabin Glove Box

    Four Station Double Box Double Side 800mm Extended Cabin Glove Box A. Acceptance standard: Under standard conditions, that is, under constant temperature of 20-25 oC, relative humidity of 65% and inert air source of 99.999%, the oxygen index of circulating water in empty tank body is less than 0.1ppm. B. The main technical indicators and configuration 1. Box body 1.1. Size: 2400mm (L) x 900mm (H) x 1000mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Aperture 0.3 micron 1.4. Butyl rubber gloves: original imported from the United States thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Tilted operating surface, 8mm safety tempered glass front window, wear resistance, corrosion resistance, good light transmission, 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure (-10mbar-10mbar) when used. 1.7. The cabinet is equipped with anti-reflection lighting energy-saving lamp, the light is soft. 1.8. The box body is provided with two layers of display board hoisting shelves 1.9. The box is provided with a porous power terminal board (Power supply: 220V±10% 50Hz±10%) 1.10. Three standard KF-40 ports can be configured on the housing. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters. 2. Transition cabin 2.1 Large and small transition cabins (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected with glove box, adopt shaft lock large transition door, easy to operate. 2.1.2 Size: large transition cabin with diameter of 360mm and length of 800mm, piston door, transition cabin with sliding tray and polishing, a small transition cabin with size of 150mm in diameter and 300mm in length, air pumping and replenishing controlled by manual valve. 2.1.3. Tray: Freely movable extension (large overcabin configuration) 2.1.4. Vacuum ≤1bar(large and small right transition cabins are required to be vacuumed, with vacuum gauge display) 3. Control system 3.1. Mode: Including self - diagnosis, power off - start feature, with pressure control and self - adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and the transition chamber at a certain set value. a) The user can set the working pressure range between +12.5 and -12.5 mbar at will, and PLC will automatically adjust the pressure of the box within the set range. Default values for operating pressure ranges are -1 to +3 millibars. b) When the case pressure is greater than 12 mbar, PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials in the case. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of glove box, convenient operation. 4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, United States UOP purification material, Germany Baode valve. The host system is integrated with modular design, automatic electronic control air circuit solenoid valve group, PLC control, circuit, circulating pump, purification column, display integrated with an independent purifier, forming a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjusting device: Through PLC touch type adjustment (heating, pumping, purification, regeneration) the whole process except 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulating fan: 0-100m³ high speed frequency conversion fan, microprocessor controlled, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material German BASF deoxygenation material 5kg, the United States UOP highly efficient water absorption material 5kg, extremely high life, to ensure that the user in the use of the product purification capacity long lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: H13 high efficiency filter with 0.3 micron aperture screen conforming to HEPA standard. 4.9. Regeneration: used to reuse the purification system and activate it; Regeneration requires a mixture of helium /H2, nitrogen /H2, or argon /H2, with H2 accounting for 10%. 5. Display system SIEMENS, Germany, unit control using Siemens PLC touch screen. Both Chinese and English can be switched. 6. Water analyzer, (imported from abroad) brand material: British MICHELL/ (according to customer use environment decision) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's Settings to achieve circulation drop. 5) Environment: -10℃ -- 50℃ 7. Oxygen analyzer, (imported from abroad) brand materials: AVCRAY (in accordance with the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000ppm 2) Environment: -10℃ -- 50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. Regardless of gas circulation or not, the oxygen sensor can continuously detect the atmosphere in the box and display the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are accurate zero, small drift, avoid other battery materials easy to be corroded; Low replacement cost (only oxygen battery replacement). 6) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic circulation function to maintain the oxygen content in the glove compartment within the user's specified range. 8. Vacuum system Added vacuum pump start-stop time control. Edwards vacuum pump, model RV12, flow 12m3/h, limit vacuum 2x10-3 millibar. The transition cabinr can be vacuumed separately and can be controlled separately at any time. (imported from abroad) 9. Box body automatic cleaning Automatic gas-controlled electroplating plate; The user sets the cleaning time, then touch the start button on the touch screen, the system will start cleaning the box, and automatically stop when the set time. 10. Organic solvent adsorption system To prevent the effect of organic solvent on the purifying column, a solvent column is connected in series to the glove box system. The medium is mainly high quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG. There are KF40 interfaces on the top and bottom of the column, which is convenient for refueling. Users can refueling by themselves. 11. Working conditions of the equipment: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory should have an independent ground wire: < 3Ω, from the equipment to the ground wire connection is recommended to use ≥10mm2 flat copper wire; 1.2. Water supply: None; 1.3. Relative humidity: < 75%; 1.4. There is no large amount of dust, corrosive, flammable and explosive gas in the room; 1.5. Equipment covers area: Length × width :3200mm× 1200mm   C. Main configuration No Configuration Unit Qty Manufacturer/brand Remarks 1 Glove box Pcs 2 TMAXCN 304 stainless steel thickness 3mm 2 Transition cabin Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc Import assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, United States UOP purification material, Germany Baode valve Import assembly 5 Display system Set 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe joint Set 1 French Rocole(France) Import 8 Pressure gauge Set 2 WIka(Germany) Import 9 PLC water analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN 304 stainless steel   The partial extension of the transition module can refer to this drawing (reference only for the transition module part).    

  • Lab2000 Glove Box Lab2000 Four Station Double Side Transition Cabin Glove Box with Siemens PLC Touch Screen

    Lab2000 Four Station Double Side Transition Cabin Glove Box with Siemens PLC Touch Screen I. Acceptance criteria: Under standard conditions, that is, constant temperature of 20-25 oC, relative humidity of 65%, and inert gas source of 99.999%, the circulating water and oxygen indexes of the empty box are all less than 0.1ppm.   II.Main technical indicators and configuration 1. Box 1.1. Dimensions: 1800mm (length) × 900mm (height) × 1000mm (width). 1.2. Material: All stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Pore size 0.3 microns 1.4. Butyl rubber gloves: imported from the United States, thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Operation surface with inclined design, 8mm safety tempered glass front window, wear-resistant, anti-corrosion, good light transmission, the sealing ring adopts 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure during use (-10mbar-10mbar) 1.7. The box is equipped with anti-reflection lighting energy-saving lamps, and the light is soft. 1.8. The box is equipped with a display board and a 2-layer hanging rack 1.9. There is a multi-hole power terminal board in the box (power supply: 220V±10% 50Hz±10%) 1.10. The cabinet can be set with 3 standard KF-40 ports. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, height 950 mm including casters, installed with swivel casters. 2. Transition cabin 2.1 Large and small transition warehouse (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected to the glove box, with a shaft-lock type large transition hatch, which is easy to operate. 2.1.2 Dimensions: diameter 390mm, length 600mm large transition cabin, piston door, sliding tray in the transition cabin, polished, another small transition cabin in the box, specifications: diameter 150mm, length 300mm, manual valve control air extraction and tonic. 2.1.3. Tray: free to move and extend (large transition cabin configuration) 2.1.4. Vacuum degree ≤ 1bar (both large and small right transition cabins are required to be evacuated with display) 3. Control system 3.1. Mode: including self-diagnosis, self-starting characteristics after power failure, with pressure control and self-adaptive functions. LCD display is used for automatic control, cycle control, password protection and vacuum chamber control. The unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and transition cabin at a certain set value. a) The user can arbitrarily set the working pressure range between +12.5 and -12.5 mbar, and the PLC will automatically adjust the box pressure within the set range. The default value for the working pressure range is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC will automatically open the safety valve to release the pressure to protect the gloves, equipment and materials in the box. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of the glove box, easy to operate. 4. Circulation system (including purification and regeneration system) 4.1. German BASF, American UOP purification material, German Baode valve. The host system integrates modular design, fully automatic electronically controlled gas circuit solenoid valve group, PLC control, circuit, circulating pump, purification, and display integrates an independent purifier to form a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjustment device: through PLC touch adjustment (heating, evacuation, purification, regeneration), the whole process does not require human monitoring except for 2.5 hours of ventilation. 4.4. Working gas: He.N2/or Ar gas (gas circulation) 4.5. Circulation fan: 0-100m³ high-speed variable frequency fan, microprocessor controlled, stainless steel device that has been pressure tested. 4.6. Purification column: single purification column, imported purification material German BASF deaerator material 5kg, American UOP high-efficiency water absorbing material 5kg, extremely high lifespan, ensuring long-lasting purification ability of the product during use. The water removal capacity is 2.2㎏ and the oxygen absorption capacity is 63L. 4.7. Purge valve: fully automatic electric valve. 4.8. Filter: H13 high-efficiency filter with 0.3 micron pore size filter mesh that meets HEPA standard. 4.9. Regeneration: It is used to re-use and activate the purification system; regeneration requires a mixture of helium/H2, nitrogen/H2 or argon/H2, of which H2 accounts for 10%. 5. Display system Germany SIEMENS, the unit control adopts Siemens PLC touch screen. Chinese and English bilingual can be switched. 6. Water analyzer, (imported from abroad) Brand material: British MICHELL / (according to the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10℃-50℃ 7. Oxygen analyzer, (imported from abroad) Brand material: American AVCRAY (according to the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) The measurement range can be set: 0-1000, ppm 2) Environment: -10℃-50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. No matter whether the gas is circulating or not, the oxygen sensor continuously detects the atmosphere in the box and displays the oxygen content in the glove box. 5) Sensor: Electrochemical material battery, which has the advantages of accurate zero point, small drift, avoiding the easy corrosion of other battery materials; low replacement cost (only oxygen battery is replaced). 6) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can select the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range. 8. Vacuum system Increase the vacuum pump start and stop time control. The vacuum pump is a British Edwards vacuum pump, model RV12, with a flow rate of 12m3/h and an ultimate vacuum of 2x10-3 mbar. The transition cabin can be evacuated separately, and can be controlled independently at any time. (imported from abroad) 9. Automatic cleaning of the box Automatic gas control electroplating board; the gas in the box is automatically cleaned by the user to set the cleaning time, and then touch the start button on the touch screen, the system will start cleaning the box, and it will automatically stop when the set time is reached. 10. Organic solvent adsorption system In order to prevent the influence of organic solvents on the purification column, a solvent column is connected in series to the glove box system. The media are mainly high-quality and high-efficiency activated carbon and activated alumina that prevents the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG, and there are KF40 interfaces on the top and bottom of the column, which is convenient for material change, and users can change the material by themselves. 11. Equipment working conditions: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory must have an independent ground wire: <3Ω, it is recommended to use a flat copper wire of ≥10mm2 for the connection from the equipment to the ground wire; 1.2. Water supply: none; 1.3. Relative humidity: <75%; 1.4. There is no large amount of dust in the room, no corrosive, flammable and explosive gas; 1.5. Equipment area: length × width: 3200mm × 1200mm   III.Main configuration No Configure Unit Qty Manufacturer/Brand Remark 1 Box Pcs 1 TMAXCN 304 stainless steel thickness 3mm 2 Transition cabin Pcs 1 TMAXCN 304 stainless steel 3 Control System Pcs 1 Germany SIEMENS Omron electronic devices, etc. Import assembly 4 Circulation system (including purification and regeneration system) Pcs 1 German BASF, American UOP purification material, German Baode valve Import assembly 5 Display system Pcs 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe interface Pcs 1 French Rocole(France) Import 8 Pressure gauge Pcs 2 WIka(Germany) Import 9 PLC Water Analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Pcs 1 TMAXCN 304 stainless steel        

  • Single Side Glove Box Lab Single Side Four Station Vaccum Glove Box with RV12 Vacuum Pump

    Lab Single Side Four Station Vaccum Glove Box with RV12 Vacuum Pump I. Acceptance criteria Under the standard condition, i.e. 20-25℃ constant temperature, 65% relative humidity, 99.999% inert gas source, the empty chamber circulating water oxygen index are reached less than 1ppm. English panel, English operating screen.   II. The main technical indicators and configuration 1.Box 1.1 Dimensions: 4800mm (L) × 900mm (H) × 750mm (W) single-sided. 4 sections of 1200 single-sided glove box linked by flange. 1.2 Material: full stainless steel structure (Type 304), thickness 3mm. 1.3 Filter: pore size 0.3 micron 1.4 Butyl rubber glove: U.S. original import thickness 0.4mm, glove mouth 8 inches, hard aluminum alloy glove mouth (after anti-corrosion treatment, anodized aluminum), diameter 220mm. 1.5 Window: tilt design operating surface, removable 8mm safety tempered glass front window, wear-resistant, anti-corrosion, good light transmission, sealing ring using 3/8 inch thick OMEGA seal. 1.6 The use of a certain positive and negative pressure can be maintained (-10mbar-10mbar) 1.7 The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is equipped with display board 2 shelves 1.9 The box is equipped with a multi-hole power supply terminal block (power supply: 220V ± 10% 50Hz ± 10%) 1.10 The box can be set up with 12 standard KF-40 interface. 1.11 Leakage rate: ≤0.001vol%/h 1.12 Steel structure support, including casters 950 mm high, installed with universal casters.   2.Transition compartment 2.1 Shape: cylindrical (304 stainless steel), connected with the glove box, with shaft lock type large transition compartment door, easy to operate. 2.2 Dimensions: 360mm diameter, 600mm long, piston door with reflective screen, transition chamber with sliding tray, polishing, the box set another small transition chamber, specifications: 150mm diameter, 300mm long, manual valve control pumping and gas replenishment. 2.3 Tray: stainless steel 260mm × 580mm, can be freely moved and extended (large over-compartment configuration) 2.4 The vacuum degree ≤ 1 bar (large and small right over-compartment are required to pump vacuum with display)   3.Control system 3.1 Mode: including self-diagnosis, power-off self-starting characteristics, with pressure control and self-adaptive function. Automatic control, cycle control, password protection, vacuum chamber control adopts LCD display. Unit control adopts Siemens PLC touch screen. 3.2 Pressure control: control the pressure of the box and transition chamber at a certain setting value. a) User can set any working pressure range between +12.5 to -12.5 mbar, PLC will automatically regulate the chamber pressure within the set range. The default value of the working pressure range is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC automatically opens a safety valve to relieve pressure to protect the gloves, equipment and materials inside the box. c) Use the foot switch to fine-tune the box pressure. 3.3 Foot pedal: It can control the pressure of the glove box and facilitate the operation.   4. Circulation system (including purification and regeneration system) 4.1 Germany BASF, the United States UOP purification materials, Germany Bauder valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve set, PLC control, circuit, circulation pump, purification live, display integrated into an independent purifier, constitute a compact, simple system. 4.2 Control: water, oxygen control in less than 1PPm 4.3 Adjustment device: Adjusted by PLC touch (heating, evacuation, purification, regeneration) the whole process except 2.5 hours ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas circulation) 4.5 Circulating fan: 0-100m³ high-speed frequency conversion fan, microprocessor control, pressure-tested stainless steel device. 4.6 Purification column: single purification column, imported purification material German BASF oxygen removal material 5kg, the United States UOP high-efficiency water absorption material 5kg, very high life degree, to ensure that the user in the use of the product's purification ability long lasting. Water removal capacity 2㎏ oxygen absorption capacity 60L. 4.7 Purification valve: fully automatic electro-pneumatic valve. 4.8 Filter: High efficiency filter with 0.3 micron aperture filter that meets HEPA standard. 4.9 Regeneration: used for reuse of purification system to activate it; regeneration requires a mixture of helium/H2, nitrogen/H2 or argon/H2, of which H2 accounts for 10%. Regeneration gas into the first flowmeter and then into the purification column.   5. Display system Germany SIEMENS, unit control adopts Siemens PLC touch screen. Bilingual Chinese and English can be switched.   6. Vacuum system Add vacuum pump start/stop time control. The vacuum pump is British Edwards vacuum pump, model RV12, flow rate 12m3/h, ultimate vacuum 2x10-3 mbar. The vacuum can be pumped to the transition chamber separately, and can be controlled separately at any time. (Imported from abroad)   7. Automatic box cleaning Automatic box cleaning function. Different nature of the gas environment replacement and misoperation into the water, oxygen fast box body automatic cleaning. Box automatic cleaning valve to the box body pipe integration at the use of KF25 containing steel wire solenoid tube firmly connected to the external interface KF25 pagoda joint.   III. The main technical indicators and configuration 1. Water analyzer, (imported from abroad) Brand material: Britain MICHELL / (according to customer use environment decision) Non-domestic or domestic assembly, third-party data to ensure the credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10℃-50℃   2. Oxygen analyzer, (foreign imports) brand material: the United States AVCRAY (according to the customer use environment to decide) Non-domestic or domestic assembly, third-party data to ensure the credibility of 1)Measurement range can be set: 0-1000, ppm 2)Environment: -10℃-50℃ 3)Accuracy: ±1% ppm 4)Installation position: oxygen sensor is installed on the box, regardless of gas circulation or not, the oxygen sensor detects the atmosphere inside the box uninterruptedly and displays the oxygen content inside the glove box. 5)Sensor: electrochemical material battery, the advantages of which are accurate zero point, small drift, avoid other battery materials easily corroded; low replacement cost (only replace the oxygen cell). 6) Display: The output of the analyzer is connected to the PLC, and the detection value is displayed on the touch screen, and the alarm value can be set. Control: Users can choose the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range.   IV. Organic solvent adsorption system In order to prevent the influence of organic solvent on the purification column, a solvent column is connected in series to the glove box system, the medium is mainly high quality and high efficiency activated carbon and activated alumina which prevents the formation of hydrofluoric acid. The organic solvent adsorption system is filled with 7KG, there is KF40 interface at the top and bottom of the column, which is convenient to change the material, and the user can change the material by himself. In order to prevent the formation of hydrofluoric acid, half of the solvent column tank is activated alumina.   V. Main configuration No. Configuration Unit Qty Manufacturer/Brand Note 1 Boxes pc 4 TMAXCN 304 stainless steel Thickness 3mm 2 Transition cabin set 1 TMAXCN 304 stainless steel 3 Control system set 1 Germany SIEMENS Omron electronic devices, etc. Imported assembly 4 Circulation system (including purification and regeneration system) set 1 German BASF, American UOP purification material, German Baode valve Imported assembly 5 Display system set 1 SIEMENS(Germany) Import 6 Gloves pairs 4 United States Import 7 Pipe interface set 1 French Rocole(France) Import 8 Pressure gauge set 1 WIka(Germany) Import 9 PLC water analyzer set 1 Michell(UK) Import 10 PLC oxygen analyzer set 1 AVCRAY(USA) Import 11 Vacuum pump set 1 RV12 Imported 12 Organic solvent adsorption set 1 TMAXCN High quality activated carbon 13 Automatic cleaning set 1 TMAXCN Gift      

  • Lab Glove Box Lab Six Stations Double Sides Vacuum Glove Box with Purification and Regeneration System

    Dual Chamber Glove Box with Gas Purification System TMAX-SDX1200-02 is a dual stainless steel glove box designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US in order to achieve a low water and oxygen concentration of lower than 1ppm, such that experiments can be conducted in an ultra clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, auto alarm, and system data log recording. TMAX-SDX1200-02 is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics. 

  • Glove Box Lab Three Glove Mouths Single Sided Glove Box with A 390mm Diameter T-transition Room/Cabin

    Lab Three Glove Mouths Single Sided Glove Box with A 390mm Diameter T-transition Room/Cabin   A. Acceptance criteria: Under the standard condition, that is, under the constant temperature of 20-25 ℃, the relative humidity of 65%, and the inert air source of 99.999%, the circulating water oxygen index of the empty tank body reaches less than 1ppm.   B. The main technical indicators and configuration 1. Box 1.1. Size: 1530mm (L) ×900mm (H) ×750mm (W) +1500mm (L) ×900mm (H) ×750mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Aperture 0.3 micron 1.4. Butyl rubber gloves: original imported from the United States thickness 0.4mm, glove mouth 8 inches, duraluminum-alloy glove mouth (anti-corrosion treatment, anodized aluminum), diameter 220mm. 1.5. Window: Inclined design operating surface, 8mm safety tempered glass front window, wear resistance, corrosion resistance, good light transmission, sealing ring with 3/8 inch thick OMEGA sealing ring. 1.6. Maintain a certain positive and negative pressure (-10mbar-10mbar) during use 1.7. The cabinet is equipped with anti-reflection lighting energy-saving lamps, and the light is soft. 1.8. The box body is provided with a display board 2-layer shelf 1.9. The box is equipped with a porous power terminal board (Power supply: 220V±10% 50Hz±10%) 1.10. Each box is equipped with four standard KF-40 ports. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters. 2. Transition cabin 2.1 T type large transition bin 2.1.1. Shape: T-shaped (304 stainless steel), linked glove box two boxes, three door design, easy to operate. 2.1.2. Dimensions: Diameter 390mm, length 700mm large transition cabin, piston door, transition cabin with sliding tray, polishing. 2.1.3. Pallet: Freely movable extension (The large transition compartment is equipped with). 2.1.4. Vacuum degree ≤1bar(Both large and small right transition compartments are required to be able to vacuum and display vacuum values). 2.2 Small transition warehouse 2.2.1. The two boxes are respectively provided with a small transition compartment, which is located in front of the T-bin. 2.2.2. Specifications: Diameter 159mm, length 300mm, manual valve control pumping and replenishing. 2.2.3. Vacuum degree ≤1bar(the vacuum gauge is required to display the vacuum in the transition chamber). 3. Control system (two sets) 3.1. Mode: Including self-diagnosis, power off self-start features, with pressure control and adaptive functions. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. The unit is controlled by Siemens PLC touch screen. 3.2. Pressure control: Control the pressure of the box and the transition chamber at a certain set value. a) The user can arbitrarily set the working pressure range between +12.5 and -12.5 mbar, and the PLC will automatically adjust the pressure of the box within the set range. The default value of the operating pressure range is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC automatically opens the safety valve to relieve the pressure and protect the gloves, equipment and materials in the box. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of the glove box, easy operation. 4.Circulation system (including purification and regeneration system) (two sets) 4.1. Germany BASF, United States UOP purification material, Germany Baode valve. The host system is integrated with modular design, automatic electronic control gas solenoid valve group, PLC control, circuit, circulating pump, purification, display integrated with an independent purifier, forming a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1ppm. 4.3 Adjustment device: through the PLC touch type adjustment (heating, evacuation, purification, regeneration) the whole process except 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulating fan: 0-100m³ high speed variable frequency fan, microprocessor controlled, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material Germany BASF deoxygenation material 5kg, the United States UOP efficient water absorption material 5kg, extremely high life, to ensure that the user in the use of the product purification capacity long-term lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: High efficiency filter with HEPA standard 0.3 micron aperture filter. 4.9, regeneration: used for purification system reuse, so that it is activated; Regeneration requires a mixture of helium /H2, nitrogen /H2, or argon /H2, with H2 accounting for 10%. The recycled gas first flows into the flowmeter and then into the purification column. 5. Display system (two sets) Germany SIEMENS, unit control using Siemens PLC touch screen. Both Chinese and English can be switched. 6.Water analyzer, (imported from abroad) Brand material: UK MICHELL/ ((two sets)) Non-domestic or domestically assembled, third-party data guarantees credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to achieve cycle drop. 5) Environment: -10℃ -50 ℃ 7.Oxygen analyzer, (imported from abroad) Brand material: AVCRAY ((two sets)) Non-domestic or domestically assembled, third-party data guarantees credibility. 1) Measurement range can be set: 0-1000, ppm 2) Environment: -10℃ -50 ℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box, regardless of gas circulation or not, the oxygen sensor continuously detects the atmosphere in the box and shows the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are zero accurate, small drift, to avoid other battery materials easy to be corroded; Low replacement cost (only oxygen battery replacement). 6) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic cycling function to maintain the oxygen content in the glove box within the user's specified range. 8. Vacuum system (two sets) Added vacuum pump start-stop time control. Vacuum pump selected British Edwards vacuum pump, model RV12, flow 12m3/h, limit vacuum 2x10-3 mbar. The transition chamber can be vacuumed separately and can be controlled separately at any time. (imported from abroad) 9. Box automatic cleaning (two sets) Automatic gas control plating plate; The user sets the cleaning time, and then touch the start button on the touch screen, the system will start cleaning the box, and automatically stop at the set time. 10. Organic solvent adsorption system (two sets) In order to prevent the influence of organic solvents on the purification column, a solvent column is connected in series to the glove box system, and the medium is mainly high-quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The organic solvent adsorption system is filled with 7KG, and there is a KF40 interface on the top and bottom of the column, which is convenient for refueling, and the user can refueling by himself. 11. Equipment working conditions: (provided by the user) 1.Power supply: two-phase three-wire AC220V, power 3Kw; 1.1 The laboratory should have an independent ground wire: < 3Ω, from the equipment to the ground wire connection is recommended to use ≥10mm2 flat copper wire; 1.2. Water supply: None; 1.3. Relative humidity: < 75%; 1.4. No large amount of dust, no corrosive, flammable and explosive gas in the room; 1.5. Equipment floor area: length × width :3700mm× 1200mm   C. The main configuration No Disposition Unit Qty Manufacturer/Brand Remark 1 Box Pcs 2 Tmaxcn 304 stainless steel thickness 3mm 2 Transition compartment Set 3 Tmaxcn 304 stainless steel (including T-bin and 2 small bins) 3 Control system Set 2 Germany SIEMENS Omron electronic devices, etc Import assembly 4 Circulation system (including purification and regeneration system) Set 2 Germany BASF, United States UOP purification materials, Germany Baode valve Import assembly 5 Display system Set 2 SIEMENS Import 6 Gloves Pcs 6 America Import 7 Pipe joint Set 2 French Rocle Import 8 Manometer Set 3 WIka, Germany Import 9 PLC water analyzer Pcs 2 Michell Import 10 PLC oxygen analyzer Pcs 2 American AVCRAY Import 11 Vacuum pump Pcs 2 RV12 Import 12 Organic solvent adsorption Set 2 Tmaxcn  304 stainless steel  D.Detail pictures      

  • Glove Box Vacuum Glove Box Single Side Single Work Station with Purification System

    Vacuum Glove Box Single Side Single Work Station with Purification System  Acceptance Criteria Under standard conditions, namely 20-25℃constant temperature, relative humidity 65%, 99.999% inert air source, empty tank circulating water oxygen index is less than 1ppm.   Main technical indicators and configuration 1. The box body 1.1. Dimensions: 1200mm (L) x 900mm (H) x 770mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: aperture 0.3 micron 1.4. Butyl rubber gloves: the thickness of the original import from the United States 0.4mm, 2 ah glove mouth 8 inches, duraluminum-alloy glove mouth (after corrosion treatment, anodized aluminum oxide), 220mm diameter. 1.5. Windows: sloped design operating surface, removable 8mm safety toughened glass front window, wear, corrosion resistance, good light transmission, and a 3/8 inch thick OMEGA seal ring. 1.6. Can maintain a certain positive and negative pressure (-10mbar-10mbar) 1.7. Box is equipped with anti - reflection lighting energy-saving lamp, soft light. 1.8. The box body is provided with display board 2 shelves 1.9. The box body is provided with a porous power supply junction board (Thai plug 220V, 50 Hz) 1.10. Four standard KF-40 ports can be installed in the box. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, 950 mm high with casters, equipped with universal casters.   2. Transition module 2.1. Shape: Cylindrical (304 stainless steel), connected to glove box, with shaft lock large transition door for easy operation. 2.2. Size: 390mm in diameter, 600mm in length large transition chamber, piston door, sliding tray in transition chamber, polishing, a small transition chamber is set in the box, specification: 150mm in diameter, 300mm in length, manual valve control of air pumping and filling. 2.3. Pallet: Free to move and extend (large transition cabin configuration) 2.4. Vacuum ≤1bar(both large and small right transition compartments require vacuum belt display)   3. Control system 3.1. Mode: including self - diagnosis, power - off self - start characteristics, with pressure control and self - adaptation functions. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the chamber and the transition chamber at a certain set point. A) The user can arbitrarily set the working pressure interval between +12.5 and -12.5 mbar, and PLC will automatically regulate the pressure of the box within the set range. The default operating pressure range is -1 to +3 mbar. B) When the box pressure is greater than 12 mbar, PLC automatically opens the safety valve to relieve pressure and protect gloves, equipment and materials in the box. C) Use foot switch to fine tune the box pressure. 3.3. Foot pedal: can control the pressure of glove box, easy to operate.   4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, United States UOP purification materials, Germany Baode valve. The host system is integrated with modular design. The automatic electronic control gas path solenoid valve set, PLC control, circuit, circulating pump, purification house and display are integrated with an independent purifier, forming a compact and simple system. 4.2. Control: water and oxygen are controlled in less than 1PPm 4.3 Adjustment device: through PLC touch type adjustment (heating, evacuation, purification, regeneration) the whole process except 2.5 hours ventilation without human monitoring. 4.4. Working gas: HE. N2/ or Ar gas (gas circulation) 4.5. Circulating fan: 0-100M ³ high speed variable frequency fan, microprocessor control, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material Germany BASF deoxygenation material 5kg, the United States UOP high-efficiency water absorption material 5kg, extremely high life degree, to ensure that users in the process of using the product's purification ability long lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: High efficiency filter with 0.3 micron aperture mesh conforming to HEPA standard. 4.9 Regeneration: used for reuse of purification system to activate it; Regeneration requires a mixture of helium /H2, nitrogen /H2 or argon /H2, with H2 accounting for 10%. And then the advanced flow meter into the purification column.   5. Display system SIEMENS, unit control adopts SIEMENS PLC touch screen. You can switch between Chinese and English. Water analyzer, (imported from abroad) brand material: British MICHELL/ (according to the customer's use of the environment decision) Non-domestic or domestic assembly, third party data to ensure credibility. 1) Measurement range: 0-1000ppm 2) Accuracy: ±1% PPM 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to achieve circulation reduction. 5) Environment: -10℃ -- 50℃   6. Oxygen analyzer, (imported from abroad) Brand material: AVCRAY (electrochemical material battery) Non-domestic or domestic assembly, third party data to ensure credibility. 1) The measurement range can be set: 0-1000ppm 2) Environment: -10℃ -- 50℃ 3) Accuracy: ±1% PPM 4) Installation position: The oxygen sensor is installed on the box, no matter whether the gas is circulating or not, the oxygen sensor can continuously detect the atmosphere in the box and display the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are accurate zero point, small drift, avoid other battery materials easy to be corroded; Low replacement cost (only oxygen batteries). 6) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 7) Control: Users can choose the automatic cycle function to maintain the oxygen content in the glove box within the user's prescribed range.   7. Vacuum system Increase the vacuum pump start and stop time control. Vacuum pump adopts British Edwards vacuum pump, model RV12, flow rate 12m3/h, limit vacuum 2x10-3 millibar. The transition chamber can be vacuumed separately and controlled individually at any time. (Imported from abroad)   8. Automatic cleaning of box Automatic air-controlled electroplating plate; The user sets the cleaning time, and then touches the start button on the touch screen, the system will start cleaning the box, and will stop automatically at the set time.   9. Organic solvent adsorption system In order to prevent the influence of organic solvents on the purification column, a solvent column was connected in series to the glove-box system. The medium was mainly high quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG. There are KF40 interfaces on the upper and lower parts of the column, which is convenient for refueling. Users can refueling by themselves.   10. Equipment working conditions :(provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥ 1.5KW; 1.1. The laboratory should have an independent ground wire: < 3ω, from the equipment to the ground wire connection is recommended to use more than 10mm2 flat copper wire; 1.2. Water supply: none; 1.3. Relative humidity: < 75%; 1.4. There is no large amount of dust, corrosive, flammable and explosive gas in the room; 1.5. Equipment floor area: length × width :2000mm× 1200mm   The main configuration No Configuration Unit Qty Manufacturer/Brand Note 1 Box Unit 1 TMAXCN 304 stainless steel Thickness 3mm 2 Transition cabin  Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc Imported assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, the United States UOP purification materials, Germany Baode valve Imported assembly 5 Display system Set 1 Germany SIEMENS Import 6 Gloves Pair 1 The United States Import 7 Pipeline interface Set 1 French Lecolor Import 8 Pressure gauge Set 1 Germany WIka Import 9 PLC water analyzer Unit 1 The British michelle Import 10 PLC oxygen analyzer Unit 1 The United States AVCRAY Import 11 Vacuum pump Unit 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN Activated carbon + activated alumina      

  • Glove Box Lab Double Station Single Side Heating Glove Box with Vacuum System

    Lab Double Station Single Side Heating Glove Box with Vacuum System  I. Acceptance criteria: Under the standard condition, that is, under the constant temperature of 20-25℃, the relative humidity of 65%, and the inert air source of 99.999%, the circulating water oxygen index of the empty tank body reaches less than 1ppm. English panel, English operation screen.   II. Main technical indicators and configuration 1. Cabinet 1.1 Size: 1800mm (L) × 900mm (H) × 750mm (W) single-sided. 1.2 Material: stainless steel structure (Type 304), thickness 3mm. 1.3 Filter: pore size 0.3 microns. 1.4 Butyl rubber glove: imported from the U.S. thickness of 0.4mm, glove mouth 8 inches, hard aluminum alloy glove mouth (anti-corrosion treatment, anodized aluminum), caliber 220mm. 1.5 Window: tilted design of the operating surface, removable 8mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring using 3/8 inch thick OMEGA seal. 1.6. Can maintain a certain positive and negative pressure (-10mbar-10mbar) when in use. 1.7. The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is equipped with a display board 2 shelves 1.9. The box is equipped with a multi-hole power terminal board (power supply: 220V ± 10% 50Hz ± 10%) 1.10. The box can be set up 3 standard KF-40 interface. 1.11. Leakage rate: ≤ 0.001vol%/h. 1.12. Steel structure bracket, including casters height 950 mm, installed with universal casters.   2. Transition cabin (large or small cabin 250℃ oven)   2.1 Shape: cylindrical (304 stainless steel), connected with the glove box, the use of shaft-locked large transition hatch, easy to operate. 2.2 Dimensions: diameter of 360mm, 600mm long oven, piston door with reflective screen, the transition chamber with a sliding tray, polished, the box is set up in another small transition chamber, specifications: diameter of 150mm, length of 300mm, manual valve control pumping and make-up air. 2.3 Tray: stainless steel 260mm × 580mm, free to move the extension (large over the cabin configuration) 2.4 Vacuum degree ≤ 1bar (large and small right over the cabin are required to vacuum with a display) 2.5 Heating mode: heating wire internal heating. 2.6 The temperature uniformity of the heating area in the chamber ≤ ± 5 ℃, when the temperature is stabilized after the temperature difference between the heating area in the oven and the set temperature: ≤ ± 5 °. 2.7 Maximum heating temperature 250±5℃. 2.8 Display precision of temperature controller: ≤±2°. 2.9 Heating chamber outside the need for water-cooled thermal insulation insulation layer, the outer wall temperature ≤ 50 ℃, and to ensure that the maintenance and replacement of convenient, water-cooled machine customers to provide their own equipment on the reserved φ10 transparent tube water-cooled joints. 2.10 The inner and outer doors of the heating chamber are insulated with multi-layer heat insulation, and the doors are of slanting type. 2.11 Temperature control of the cabin: intelligent digital temperature control instrument table, to achieve automatic uniform heating and heat preservation and other functions; with over-temperature fault alarm and automatic power-off function.   3. Control system 3.1 Methods: including self-diagnosis, power failure self-starting characteristics, with pressure control and self-adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2 Pressure control: control the pressure of the box and transition chamber at a certain set value. a) Users can set any working pressure interval between +12.5 and -12.5 mbar, and PLC will automatically regulate the box pressure within the set range. The default value of the working pressure interval is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials inside the box. c) Use the foot switch to fine-tune the box pressure. 3.3 Foot pedal: can control the pressure of the glove box, easy to operate.   4. Circulation system (including purification and regeneration system) 4.1 Germany BASF, the United States UOP purification materials, Germany Baode valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve group, PLC control, circuits, circulating pumps, purification columns, monitors integrated into an independent purifier, constituting a compact, simple system . 4.2. Control: water, oxygen control in less than 1PPm 4.3. Adjustment device: through the PLC touch regulation (heating, evacuation, purification, regeneration) in addition to the whole process of 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulation fan: 0-100m³ high-speed frequency conversion fan, microprocessor control, pressure-tested stainless steel device. 4.6 Purification column: single purification column, imported purification material Germany BASF deoxidizing material 5kg, American UOP high efficient water absorption material 5kg, very high life span degree, to ensure that the user in the use of the product in the process of purification of the product ability to long lasting. In addition to the water capacity of 2.2㎏ oxygen absorption capacity of 63L. 4.7 Purification valve: full-automatic electropneumatic valve. 4.8 Filter: It adopts the high efficiency filter with 0.3 micron aperture in accordance with HEPA standard. 4.9 Regeneration: used to purify the system again, so that the activation; regeneration needs helium / H2, nitrogen / H2 or argon / H2 gas mixture, of which H2 accounted for 10%. Regenerated gas into the flow meter and then into the purification column.   5. Display system Germany SIEMENS, unit control adopts Siemens PLC touch screen. Chinese and English bilingual can be switched.   6. Vacuum system Increase the start-stop time control of vacuum pump. The vacuum pump adopts British Edwards vacuum pump, model RV12, flow rate 12m3/h, ultimate vacuum 2x10-3 mbar. It can vacuum the transition chamber separately and realize separate control at any time. (Imported from abroad)   7. Automatic box body cleaning Automatic box body cleaning function. Different nature of the gas environment replacement and misoperation into the water, oxygen fast box body automatic cleaning. Box automatic cleaning valve to the box body piping integration using KF25 steel wire pipe firmly connected to the external interface KF25 Pagoda connector.   III. Main technical indicators and configuration 1. Water analyzer, (imported from abroad) brand material: British MICHELL / (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10 ℃ -50 ℃   2. Oxygen analyzer, (imported from abroad) brand material: the United States AVCRAY (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000ppm 2)Environment: -10℃-50 3)Accuracy: ±1% ppm 4)Installation position: Oxygen sensor is installed on the box, regardless of the gas cycle or not, the oxygen sensor uninterruptedly detects the atmosphere inside the box and displays the oxygen content inside the glove box. 5)Sensor: electrochemical material battery, its advantages are accurate zero point, small drift, avoid other battery material is easy to be corroded; low replacement cost (only replace the oxygen battery). 6) Display: The output of the analyzer is connected to PLC, the detected value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range.   IV. Organic solvent adsorption system In order to prevent the impact of organic solvents on the purification column, a solvent column in series to the glove box system, the medium is mainly high-quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. Organic solvent adsorption system filling volume of 7KG, in the column on the lower part of the KF40 interface, easy to change the material, the user can change the material, in order to prevent the formation of hydrofluoric acid, solvent column tank half of activated alumina.   V. Main configurations No Configuration Unit Qty Manufacturer/Brand Remark 1 Box Pcs 1 TMAXCN 304 stainless steel thickness 3mm 2 Heating chamber Set 2 TMAXCN Φ360*600/φ159*300 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc. Import assembly 4 Circulation system (including purification and regeneration system) Set 1 German BASF, American UOP purification material, German Baode valve Import assembly 5 Display system Set 1 SIEMENS(Germany) Import 6 Gloves Pair 2 United States Import 7 Pipe joint Set 1 French Rocole(France) Import 8 Pressure gauge Set 1 WIka(Germany) Import 9 PLC water analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Solvent adsorption system Set 1 TMAXCN High quality activated carbon 13 Automatic cleaning Set 1 TMAXCN Give away        

  • Glove Box Desktop Single Side Single Station Glove Box with Water and Oxygen Monitoring System

    Desktop Single Side Single Station Glove Box with Water and Oxygen Monitoring System  Composition of the equipment The equipment mainly consists of a closed box, a set of transition chamber, a set of circulation system (including purification and regeneration system), a set of water and oxygen monitoring system, and a set of control system.   Glove box equipment schematic diagram     Product advantages and features 1. Glove box has beautiful design, compact structure and fine workmanship; 2. Glove box purification system, so that water, oxygen <1ppm 3. The equipment runs stably and can be operated continuously for a long time; 4. Simple operation; low operation and maintenance costs; 5. Glove box each part of specialization, standardization, scale production; 6. Products for a variety of special requirements of customers; 7. All parts are strictly audited and controlled; 8. Rich design and manufacturing experience;   Technical program for Lab2000     I. Acceptance criteria: In the standard condition, i.e., 20-25℃ constant temperature, 65% relative humidity, 99.999% inert gas source, the empty box body circulating water oxygen indicators are reached less than 1ppm.   II. Main technical indicators and configuration 1. Box 1.1 Size: 800mm (L) × 720mm (H) × 650mm (W). 1.2 Material: stainless steel structure (Type 304), thickness 3mm. 1.3 Filter: pore size 0.3 micron. 1.4 Butyl rubber glove: imported from the U.S. thickness of 0.4mm, glove mouth 8 inches, hard aluminum alloy glove mouth (anti-corrosion treatment, anodized aluminum), caliber 220mm. 1.5 Window: tilted design of the operating surface, removable 8mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring using 3/8 inch thick OMEGA sealing ring 1.6. Can maintain a certain positive and negative pressure (-10mbar-10mbar) when in use. 1.7. The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8. The box is equipped with a multi-hole power terminal board (power supply: 220V ± 10% 50Hz ± 10%) 1.9. The box can be equipped with 3 standard KF-40 ports. 1.10. Leakage rate: ≤ 0.001 vol%/h. 1.11. No stand, can be operated on the table.   2. Transition cabinet 2.1. Shape: square (304 stainless steel), connected with the glove box, the inner door adopts sliding door, the outer door adopts flush type, easy to operate. 2.2 Dimensions: width * height * length = 250 * 250 * 400mm, the transition chamber has a sliding tray, polished, automatic control of pumping and filling. 2.3. Tray: stainless steel 190mm × 450mm, free to move the extension (used for large transition cabinet) 2.4 Vacuum degree ≤ 1bar (the large and small transition cabinets on the right are required to be vacuumed and displayed with a vacuum gauge)   3. Control system 3.1. Mode: including self-diagnosis, power failure self-starting characteristics, with pressure control and self-adaptive function. Automatic control, cycle control, password protection, vacuum chamber control adopts LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and transition chamber at a certain set value. a) Users can set the working pressure interval arbitrarily between +12 and -12 millibars, PLC will automatically regulate the box pressure in the set range. The default value of the working pressure interval is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC automatically opens the safety valve to relieve pressure and protect gloves, equipment and materials inside the box. c) Use the foot switch to fine tune the box pressure. 3.3. Foot pedal: can control the pressure of the glove box, easy to operate.   4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, the United States UOP purification materials, Germany Baode valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve group, PLC control, circuit, circulating pumps, purification of the residence, the display is integrated into an independent purifier, constituting a compact, simple system . 4.2. Control: water, oxygen control in less than 1PPm 4.3. Adjustment device: through the PLC touch regulation (heating, evacuation, purification, regeneration) in addition to the whole process of 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulation fan: 0-30m³ high-speed frequency conversion fan, microprocessor control, after the pressure test stainless steel device. 4.6 Purification column: single purification column, imported purification material Germany BASF deoxidizing material 5kg, American UOP high efficient water absorbing material 5kg, very high life span degree, ensure the user in the use of the product in the process of the purification ability of the long lasting. In addition to the water capacity of 2.2㎏ oxygen absorption capacity of 63L. 4.7 Purification valve: full-automatic electropneumatic valve. 4.8 Filter: It adopts the high efficiency filter with 0.3 micron aperture in accordance with HEPA standard. 4.9 Regeneration: used to purify the system for reuse and activation; regeneration requires helium/H2, nitrogen/H2 or argon/H2 gas mixture, of which H2 accounts for 10%.   5. Display system Germany SIEMENS, unit control adopts Siemens PLC touch screen. English and Chinese bilingual can be switched.   6. Water analyzer, (imported from abroad) brand material: Britain MICHELL / (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% FS 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10 ℃ -50 ℃   7. Oxygen analyzer, PLC oxygen analyzer (U.S. AVDRAY electrochemical analyzer) Error: ± 1% FS non-domestic or domestic assembly, third-party data to ensure credibility. 1)Measurement range can be set: 0-1000, ppm 2)Environment: -10℃ -50℃ 3)Accuracy: ±1% ppm   8. Box automatic cleaning Automatic gas control plating plate; box gas automatic cleaning function users set the cleaning time, and then touch the start button on the touch screen, the system will begin to clean the box, to the set time is automatically stopped. Increase the vacuum pump start and stop time control. Automatic box cleaning function. Different nature of the gas environment replacement and misoperation into the water, oxygen, fast box body automatic cleaning. The box automatic clear valve to the box piping integration to KF25 steel wire with steel tubes firmly connected to the external KF25 Pagoda connector.   9. Vacuum system Vacuum pump selection Feiyue VRD-16, pumping speed of 16m³/h, can be on the cabinet vacuum.   Working conditions of the equipment: (provided by the user) 1. Power supply: two-phase three-wire AC220V, power ≥ 1.8Kw; 2. Laboratory to have an independent ground: <3Ω, from the equipment to the ground connection is recommended to use ≥ 10mm2 flat copper wire; 3. Water supply: no; 4. Relative humidity: <75%; 5. Indoor no large amounts of dust, no corrosive, flammable and explosive gases; 6. Inert gas: working gas requirements to provide 0.4-0.6mpa, mixed gas working pressure 0.01-0.05mpa; 7. During the installation and commissioning of the gas demand side to provide, the purity of 99.999% working gas 2 bottles (40L / bottle); regeneration gas (hydrogen content of 5% -10% and the working gas mixture) 1 bottle, 40L / bottle; 8. Equipment footprint: length × width: 1200mm × 1000mm 9. Load-bearing requirements: ≤300kg/m³   Main configurations and scope of supply No. Main configuration and scope of supply configuration Units Amount Manufacturer/Brand Remarks 1 Enclosure Piece 1 TMAXCN 316 Stainless Steel Thickness 3mm 2 Excess chamber Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronics, etc. Imported assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, the United States UOP purification materials, Germany Bauder valve Import assembly 5 Display system Set 1 Germany SIEMENS Imported 6 Gloves Pair 1 USA Imported 7 Pressure gauges Set 1 Wika, Germany Imported 8 PLC water analyzer Piece 1 Michell, UK With factory inspection report 9 PLC Oxygen Analyzer Piece 1 Avcray, USA Imported 10 Vacuum Pumps Piece 1 Flyover Domestic 11 Oil Mist Filter Piece 1 TMAXCN Domestic 12 Pressure Gauges Set 1 Wika, Germany Imported                     

  • Glove Box Lab Three Glove Ports Single Side Glove Box with Purification System and Cryogenic Cold Trap

    Lab Three Glove Ports Single Side Glove Box with Purification System and Cryogenic Cold Trap  I. Acceptance criteria: In the standard condition, i.e., 20-25℃ constant temperature, 65% relative humidity, 99.999% inert gas source, the empty box body circulating water oxygen indicators are reached less than 1ppm.   II. Main technical indicators and configuration 1. Box 1.1 Size: 1500mm (L) × 900mm (H) × 750mm (W). 1.2 Material: stainless steel structure (Type 304), thickness 3mm. 1.3 Filter: pore size 0.3 micron. 1.4 Butyl rubber glove: imported from the U.S. thickness of 0.4mm, glove mouth 8 inches, hard aluminum alloy glove mouth (anti-corrosion treatment, anodized aluminum), caliber 220mm. 1.5 Window: tilted design of the operating surface, 8mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring using 3/8 inch thick OMEGA seal. 1.6 Use can maintain a certain positive and negative pressure (-10mbar-10mbar) 1.7 The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is equipped with a display board 2 shelves 1.9 The box is equipped with a multi-hole power terminal board (power supply: 220V ± 10% 50Hz ± 10%) 1.10 The box can be set up 4 standard KF-40 interface. 1.11 Leakage rate: ≤ 0.001vol%/h. 1.12 Steel structure bracket, including casters height 950 mm, installed with universal casters.   2. Transition cabinet 1 2.1 Large and small transition cabinet (right side) 2.1.1 Shape: cylindrical (304 stainless steel), connected with the glove box, with a shaft-locked large transition cabinet door, easy to operate. 2.1.2 Size: diameter 360mm, 600mm long large transition cabinet, piston door, transition cabinet with a sliding tray, polished, the box is set up in another small transition cabinet, specifications: diameter 150mm, 300mm long, manual valve control pumping and replenishment. 2.1.3 Tray: free to move the extension (used for large transition cabinet) 2.1.4 Vacuum degree ≤ 1bar (the large and small transition cabinets on the right are required to be vacuumed and displayed with a vacuum gauge)   3. Control system 3.1 Methods: including self-diagnosis, power failure self-starting characteristics, with pressure control and self-adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2 Pressure control: control the pressure of the box and transition chamber at a certain set value. a) Users can set any working pressure interval between +12.5 and -12.5 mbar, and PLC will automatically regulate the box pressure within the set range. The default value of the working pressure interval is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC automatically opens the safety valve to relieve pressure and protect gloves, equipment and materials inside the box. c) Use the foot switch to fine-tune the box pressure. 3.3 Foot pedal: can control the pressure of the glove box, easy to operate.   4. Circulation system (including purification and regeneration system) 4.1 Germany BASF, the United States UOP purification materials, Germany Baode valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve group, PLC control, circuits, circulating pumps, purification of the residence, the display is integrated into an independent purifier, constituting a compact, simple system. 4.2 Control: water, oxygen control in less than 1PPm 4.3 Adjustment device: through the PLC touch regulation (heating, evacuation, purification, regeneration) in addition to the whole process of 2.5 hours of ventilation without human monitoring. 4.4 Working gas: He.N2/ or Ar gas (gas cycle) 4.5 Circulation fan: 0-100m³ high-speed frequency conversion fan, microprocessor control, after the pressure test stainless steel device. 4.6 Purification column: single purification column, imported purification material Germany BASF deoxidizing material 5kg, American UOP high efficient water absorbing material 5kg, very high life span degree, ensure the user in the use of the product in the process of purification of the product ability to long lasting. In addition to the water capacity of 2.2㎏ oxygen absorption capacity of 63L. 4.7 Purification valve: full-automatic electropneumatic valve. 4.8 Filter: It adopts the high efficiency filter with 0.3 micron aperture in accordance with HEPA standard. 4.9 Regeneration: used to purify the system again, so that the activation; regeneration needs helium / H2, nitrogen / H2 or argon / H2 gas mixture, of which H2 accounted for 10%. Regenerated gas into the flow meter and then into the purification column.   5. Display system Germany SIEMENS, unit control using Siemens PLC touch screen. English and Chinese bilingual can be switched.   6. Water analyzer, (imported from abroad) brand material: Britain MICHELL / (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10 ℃ -50 ℃   7. Oxygen analyzer, (imported from abroad) Brand Material: U.S. AVCRAY (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000, ppm 2)Environment: -10℃-50 3)Accuracy: ±1% ppm 4)Installation position: Oxygen sensor is installed on the box, regardless of gas circulation or not, the oxygen sensor uninterruptedly detects the atmosphere inside the box and displays the oxygen content inside the glove box. 5)Sensor: electrochemical material battery, its advantages are accurate zero point, small drift, avoid other battery material is easy to be corroded; low replacement cost (only replace the oxygen battery). 6)Display: The output of the analyzer is connected to PLC, the detected value is displayed on the touch screen, and the alarm value can be set. 7) Control: The user can choose the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range.   8. Vacuum system Increase the start-stop time control of vacuum pump. The vacuum pump is British Edwards vacuum pump, model RV12, flow rate 12m3/h, ultimate vacuum 2x10-3 mbar. It can vacuum the transition chamber separately and realize separate control at any time. (Imported from abroad)   9. Box automatic cleaning Automatic gas control plating plate; box gas automatic cleaning function users set the cleaning time, and then touch the start button on the touch screen, the system will begin to clean the box, to the set time is automatically stopped.   10. Organic solvent adsorption system In order to prevent the impact of organic solvents on the purification column, a solvent column in series to the glove box system, the medium is mainly high-quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. Organic solvent adsorption system filling capacity of 7KG, in the column on the lower part of the KF40 interface, easy to change the material, the user can change their own material.   11. Equipment working conditions: (provided by the user) 1.0 Power supply: two-phase three-wire AC220V, power ≥ 1Kw; 1.1 Laboratory to have an independent ground: <3Ω, from the equipment to the ground connection is recommended to use ≥ 10mm2 flat copper wire; 1.2 Water supply: no; 1.3 Relative humidity: <75%; 1.4 Indoor no large amount of dust, no corrosive, flammable and explosive gases; 1.5 Equipment footprint: length × width: 2500mm × 1200mm   12. 5℃-80℃ low-temperature cold bath   Basic parameters Cavity volume: 4.7 liters, size: φ200 * 150mm Temperature control range: +0 ℃ ~ -80 ℃ Display: plc integrated display temperature Internal material: 304 stainless steel, brushed surface External material: 1.5mm stainless steel plate, plastic spraying Cooling method: cold bath pot periphery evenly arranged copper tubes, copper tubes into the coolant Refrigeration mode: imported compressor Refrigerant: R404 R23 Temperature control range: +5 ℃ ~ -80 ℃ Temperature fluctuation:±0.1℃ Cooling capacity: 275-3150W Heating power: 800W Cooling power: 2840W Circulation power: 100W Circulation pump flow: 25L/min Installation: embedded in the bottom of the glove box Product features Original hermetic compressor of international famous manufacturer, with advanced performance and reliable quality; Refrigeration unit professional relays, protectors, capacitors, etc. are imported original high-quality equipment to ensure reliability and service life; Digital display temperature control, simple and eye-catching operation; Circulation system is made of stainless steel, with anti-corrosion, anti-rust, anti-temperature liquid pollution;     Cold trap for single-sided, double-station glove boxes (just to give you a reference to where the cold trap is placed)   III. Main configurations No. Configuration Units Amount Manufacturer/Brand Remarks 1 Box Piece 1 TMAXCN 304 Stainless Steel Thickness 3mm 2 Transition cabinet Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS OMRON electronic devices, etc. Imported assembled 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, the United States UOP purification materials, Germany Bauder valve Imported assembled 5 Display system Set 1 Germany SIEMENS Imported 6 Gloves Pieces 3 U.S.A. Imported 7 Pipe connections Set 1 France Legris Imported 8 Pressure gauges Set 1 Germany WIka Import 9 PLC Water analyzer Piece 1 Michell, UK Import 10 PLC Oxygen analyzer Piece 1 AVCRAY, USA Import 11 Vacuum pumps Piece 1 RV12 Imported 12 Organic solvent adsorption Set 1 TMAXCN 304 Stainless Steel 13 Low temperature cold trap Piece 1 Century Iowa Imported                     

  • Glove Box Single Side Glove Box with Renewable Organic Solvent Adsorption System and Low Temperature Cold Trap

    Single Side Glove Box with Renewable Organic Solvent Adsorption System and Low Temperature Cold Trap  Images are for reference only(The actual picture is a single-sided three-station glove box rather than a single-sided two-station)   I. Acceptance criteria: In the standard condition, that is, 20-25℃ constant temperature, relative humidity of 65%, 99.999% of the inert gas source, the empty box body circulating water oxygen indicators are reached less than 1ppm.   II. Main technical indicators and configuration 1. Box (front window can be lifted) 1.1 Size: 1500mm (L) × 900mm (H) × 750mm (W). 1.2 Material: stainless steel structure (Type 304), thickness 3mm. 1.3 Filter: pore size 0.3 micron. 1.4 Butyl rubber glove: imported from the U.S. thickness of 0.4mm, glove mouth 8 inches, hard aluminum alloy glove mouth (anti-corrosion treatment, anodized aluminum), caliber 220mm. 1.5 Window: tilted design of the operating surface, 8mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring using 3/8 inch thick OMEGA seal. 1.6. Use can maintain a certain positive and negative pressure (-10mbar-10mbar) 1.7. The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is equipped with a display board 2 shelves 1.9. The box is equipped with a multi-hole power terminal board (power supply: 220V ± 10% 50Hz ± 10%) 1.10. The box can be set up 4 standard KF-40 interface. 1.11. Leakage rate: ≤ 0.001vol%/h. 1.12. Steel structure bracket, including casters height 950 mm, installed with universal casters.   2. Transition Cabinet 1 2.1 Large and small transition cabinet(right side) 2.1.1 Shape: cylindrical (304 stainless steel), connected with the glove box, with a shaft-locked large transition cabinet door, easy to operate. 2.1.2 Size: diameter 360mm, 600mm long large transition cabinet, piston door, transition cabinet with a sliding tray, polished, the box is set up in another small transition cabinet, specifications: diameter 150mm, 300mm long, manual valve control pumping and replenishment. 2.1.3. tray: free to move the extension (used for large transition cabinet) 2.1.4 Vacuum degree ≤ 1bar (the large and small transition cabinets on the right are required to be vacuumed and displayed with a vacuum gauge)   3. Control system 3.1.1 Mode: including self-diagnosis, power failure and self-starting characteristics, with pressure control and self-adaptation function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and transition chamber at a certain set value. a) Users can set any working pressure interval between +12.5 and -12.5 mbar, and PLC will automatically regulate the box pressure within the set range. The default value of the working pressure interval is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC automatically opens the safety valve to relieve pressure and protect gloves, equipment and materials inside the box. c) Use the foot switch to fine tune the box pressure. 3.3. Foot pedal: can control the pressure of the glove box, easy to operate.   4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, the United States UOP purification materials, Germany Baode valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve group, PLC control, circuits, circulating pumps, purification of the residence, the display is integrated into an independent purifier, constituting a compact, simple system. 4.2. Control: water, oxygen control in less than 1PPm 4.3. Adjustment device: through the PLC touch regulation (heating, evacuation, purification, regeneration) in addition to the whole process of 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulation fan: 0-100m³ high-speed frequency conversion fan, microprocessor control, after the pressure test stainless steel device. 4.6 Purification column: single purification column, imported purification material Germany BASF deoxidizing material 5kg, American UOP high efficient water absorbing material 5kg, very high life span degree, ensure the user in the use of the product in the process of purification of the product ability to long lasting. In addition to the water capacity of 2.2㎏ oxygen absorption capacity of 63L. 4.7 Purification valve: full-automatic electropneumatic valve. 4.8 Filter: It adopts the high efficiency filter with 0.3 micron aperture in accordance with the HEPA standard. 4.9 Regeneration: used to purify the system again, so that the activation; regeneration needs helium / H2, nitrogen / H2 or argon / H2 gas mixture, of which H2 accounted for 10%. Regenerated gas into the flow meter and then into the purification column.   5. Display system Germany SIEMENS, unit control adopts Siemens PLC touch screen. English and Chinese bilingual can be switched.   6. Water analyzer, (imported from abroad) brand material: Britain MICHELL / (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10 ℃ -50 ℃   7. Oxygen analyzer, (imported from abroad) Brand Material: U.S. AVCRAY (in accordance with the customer's use of environmental decisions) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000, ppm 2)Environment: -10℃-50 3)Accuracy: ±1% ppm 4)Installation position: Oxygen sensor is installed on the box, regardless of gas circulation or not, the oxygen sensor uninterruptedly detects the atmosphere inside the box and displays the oxygen content inside the glove box. 5)Sensor: electrochemical material battery, its advantages are accurate zero point, small drift, avoid other battery material is easy to be corroded; low replacement cost (only replace the oxygen battery). 6) Display: The output of the analyzer is connected to PLC, the detected value is displayed on the touch screen, and the alarm value can be set. Control: The user can select the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range.   8. Vacuum system Increase the start-stop time control of vacuum pump. The vacuum pump is British Edwards vacuum pump, model RV12, flow rate 12m3/h, ultimate vacuum 2x10-3 mbar. It can vacuum the transition chamber separately and realize separate control at any time. (Imported from abroad)   9. Box automatic cleaning Automatic gas control plating plate; box gas automatic cleaning function users set the cleaning time, and then touch the start button on the touch screen, the system will begin to clean the box, to the set time is automatically stopped.   10. Organic solvent adsorption system (renewable) In order to prevent the impact of organic solvents on the purification column, a solvent column in series to the glove box system, the medium is mainly high-quality and efficient activated carbon and prevent the formation of hydrofluoric acid activated alumina. Organic solvent adsorption system filling capacity of 7KG Renewable solvent adsorption system, through the PLC touch regulation (heating, evacuation, purification, regeneration) and other processes.   11. 5℃--80℃ low-temperature cold bath pot   Basic parameters Cavity volume: 4.7 liters, size: φ200*150mm Temperature control range:+0℃~-80℃ Display: plc integrated display temperature Internal material: 304 stainless steel, brushed surface External material: 1.5mm stainless steel plate, plastic spraying Cooling method: cold bath pot periphery evenly arranged copper tubes, copper tubes into the coolant Refrigeration mode: imported compressor Refrigerant: R404 R23 Temperature control range: +5 ℃ ~ -80 ℃ Temperature fluctuation:±0.1℃ Cooling capacity: 275-3150W Heating power: 800W Cooling power: 2840W Circulation power: 100W Circulation pump flow: 25L/min Installation: embedded in the bottom or side of the glove box Product features Original hermetic compressor of international famous manufacturer, with advanced performance and reliable quality; Refrigeration unit professional relays, protectors, capacitors, etc. are imported original high-quality equipment to ensure reliability and service life; Digital display temperature control, simple and eye-catching operation; Circulation system is made of stainless steel, with anti-corrosion, anti-rust, anti-temperature liquid pollution;   12. Equipment working conditions: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥ 4.5Kw; 1.1. laboratory to have an independent ground: <3Ω, from the equipment to the ground connection is recommended to use ≥ 10mm2 flat copper wire; 1.2. water supply: no; 1.3. Relative humidity: <75%; 1.4. Indoor no large amount of dust, no corrosive, flammable and explosive gases; 1.5. Equipment footprint: length × width: 2500mm × 1200mm   III. Main configurations No. Configuration Unit Amount Manufacturer/Brand Remarks 1 Box Piece 1 TMAXCN 304 Stainless Steel Thickness 3mm 2 Transition cabinet Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronics, etc. Imported assembled 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, the United States UOP purification materials, Germany Bauder valve Imported assembled 5 Display system Set 1 Germany SIEMENS Import 6 Gloves Piece 3 USA Import 7 Pipe connections Set 1 France Legris Import 8 Pressure gauges Set 1 WIka, Germany Import 9 PLC Water Analyzer Piece 1 Michell, UK Import 10 PLC Oxygen Analyzer Piece 1 AVCRAY, USA Import 11 Vacuum pumps Piece 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN 304 stainless steel 13 Low Temperature Cold Well Set 1 Century Iowa Outsourcing remodeling                       

  • Glove Box Single Station Cleaning Glove Box without Oxygen Water Sensor and Purification System

    Single Station Cleaning Glove Box without Oxygen Water Sensor and Purification System (without purification system, water oxygen content <50ppm, without water oxygen analyzer)   I. Glove box standard configuration and main technical indicators 1. Box 1.1 Box size: 1200 (L) * 750 (W) * 900 (H) mm 1.2 Material: all stainless steel structure (Type 304), thickness 3mm, inner surface brushed. 1.3 2 Glove ports: 220mm in diameter, made of hard aluminum alloy with anti-corrosion treatment. 1.4 Gloves: American brand, glove caliber 8 inches, thickness 0.4 mm, butyl rubber material. 1.5 Window: front observation window (corrosion-resistant), tilted design of the operating surface, removable 8 mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring with 3/8 inch thick OMEGA seal. 1.6 Can maintain a certain pressure (0-12mbar) when using. 1.7 The box is equipped with anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is preset with 1 multi-hole power terminal board (power supply: 220V±10% 50Hz±10%) 1.9 5 Standard KF-40 interfaces are set in the box for accessing liquid, gas, signal, etc. 1.10 Bracket: with casters, height 950mm. casters with leveling, moving, fixed and other functions. 1.11 Shelf: two adjustable stainless steel brackets behind.   2. Transition cabinet 2.1.Shape: cylindrical (304 stainless steel), and the glove box flange connection, the use of shaft-locked large transition cabinet 10mm thick, the gas of the spring diagonal pull easy to operate. 2.2. Size: diameter 360mm, 600mm long large transition cabinet, piston door, transition cabinet with a sliding tray, polished; 2.3. box set up a small transition cabinet on the right side, the right side of the specifications: diameter 150mm, length 300mm, manual valve control pumping and make-up air; 2.4. Tray: stainless steel, free to move the extension (used for large transition cabinet) 2.5 Vacuum ≤ 1bar (large and small right over the cabin are required to vacuum with display)   3. Control system 3.1 Inlet and outlet are controlled by solenoid valve. 3.2 Pressure control: control box pressure at a set value (0-12mbar), automatic pressure control. 3.3 Foot pedal: can control the pressure of the glove box, easy to operate. 3.4 The box is equipped with anti-reflective lighting energy-saving lamps, soft light.   4. Vacuum system The vacuum pump is British Edwards vacuum pump, model RV12, flow rate 12m3/h, ultimate vacuum 2x10-3 millibar. It can vacuum the transition chamber and realize separate control at any time. (Imported from abroad)   Product Configuration No. Configuration Unit (of measure) Amount Manufacturer/Brand Remarks 1 Boxes Set 1 TMAXCN 304 stainless steel, 3mm thick 2 Large transition cabinet  Set 1 TMAXCN Φ360*600 3 Small transition cabinet  Set 1 TMAXCN Φ150*300 4 Tempered glass window Set 1 TMAXCN Toughened glass 5 Glove ports Pcs 2 TMAXCN Hard Aluminum Alloy 6 Gloves Pair 1 American Guardian Imported 7 Power connection and lighting system inside the box Set 1 TMAXCN/Shenzhen MingKeMing Lighting, anti-reflective lighting energy-saving lamps Domestic 8 Pipe connections Set 1 France Legris Original import 9 Pressure gauge Sets 2 Germany WIka Original import 10 Shelf Sets 2 TMAXCN 304 stainless steel, 3mm thick 11 Pressure transducers Set 1 ±12.5kpa Customized 12 Solenoid valves Sets 2 Germany Bauder Imported            

  • Glove Box Explosion Proof Double Station Stainless Steel Vacuum Glove Box with HF Adsorption Device

    Explosion Proof Double Station Stainless Steel Vacuum Glove Box with HF Adsorption Device (the equipment as a whole prohibit copper and zinc) 1. Cabinet 1.1 Dimensions: 2400mm (L) × 900mm (H) × 770mm (W). 1.2 Material: main stainless steel structure (Type 316L) thickness 3mm. 1.3 Filter: pore size 0.3 micron 1.4 Butyl rubber glove: the thickness of 0.4mm imported from the United States, glove mouth 8 inches, hard aluminum alloy glove mouth (after anti-corrosion treatment, anodic oxidation of aluminum, electrolyte and organic solvents resistant to corrosion), caliber 220mm. 1.5 Window: tilted design of the operating surface, removable 8mm safety tempered glass front window, wear-resistant, corrosion-resistant, good light transmission, sealing ring using 3/8 inch thick OMEGA seal; paste anti-corrosion film. 1.6. Use can maintain a certain positive and negative pressure (-10mbar-10mbar) 1.7. The box is equipped with explosion-proof and anti-reflective lighting energy-saving lamps, soft light. 1.8 The box is equipped with a display board 2 adjustable shelves (rear) 1.9 The box is equipped with explosion-proof socket 2 (power supply: 220V ± 10% 50Hz ± 10%) 1.10. 8 KF-40 ports are set in the box. 1.11. Leakage rate: ≤ 0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters, the whole package board. 1.13. A φ159mm cover is customized at the bottom of the box. After opening the cover, there is a hopper to transfer materials downward, and the bottom of the hopper adopts DN50 flange to connect with the DN50 automatic valve of the customer.   2. Transition cabinet (right side equipped) 2.1. Shape: cylindrical (304 stainless steel), connected with the glove box, with a shaft-locked large transition cabinet, easy to operate. 2.2. Size: diameter 390mm, 600mm long large transition cabinet, piston door, transition cabinet with a sliding tray, polished; 2.3. The right side of the box set up a small transition cabinet, the right side of the specifications: diameter 150mm, length 300mm, manual valve control pumping and make-up air. 2.4. Tray: stainless steel, can be freely moved to extend (used for large transition cabinet). 2.5 Vacuum degree ≤ 1bar (the large and small transition cabinets on the right are required to be vacuumed and displayed with a vacuum gauge) vacuum table using Germany WIKA. 2.6. The transmission parts of the large compartment adopt PTFE.   3. Control system (placed in the explosion-proof cabinet, explosion-proof processing explosion-proof level dII BT4) 3.1.Methods: including self-diagnosis, power failure and self-start characteristics, with pressure control and self-adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: The pressure sensor HALSTRUP is used to control the pressure of the chamber at a certain set value. a) The user can set the working pressure interval arbitrarily between +12.5 and -12.5 millibars, and the PLC will automatically regulate the box pressure within the set range. The default value of the working pressure interval is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials inside the box. c) Use the foot switch to fine-tune the box pressure. 3.3. Explosion-proof foot pedal: can control the pressure of the glove box, convenient operation.   4. Circulation system (placed in explosion-proof cabinet, including purification and regeneration system) 4.1 Germany BASF, the United States UOP purification materials, Germany Baode valve. Host system integrated modular design, fully automatic electronically controlled gas solenoid valve group, PLC control, circuit, circulating pumps, purification of the residence, the display is integrated into an independent purifier, constituting a compact, simple system. 4.2. Control: water, oxygen control in less than 1PPm 4.3. Adjustment device: through the PLC touch regulation (heating, evacuation, purification, regeneration) in addition to the whole process of 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulation fan: 0-100m³ high-speed frequency conversion fan, microprocessor control, after the pressure test stainless steel device. 4.6 Purification column: single purification column, imported purification material Germany BASF deoxidizing material 5kg, American UOP high efficient water absorbing material 5kg, very high life span degree, ensure the user in the use of the product in the process of purification of the product ability to long lasting. In addition to the water capacity of 2.2㎏ oxygen absorption capacity of 60L. 4.7 Purification valve: full-automatic electro-pneumatic valve. 4.8 Filter: It adopts the high efficiency filter with 0.3 micron aperture in accordance with HEPA standard. 4.9 Regeneration: used to purify the system for reuse and activation; regeneration requires helium/H2, nitrogen/H2 or argon/H2 gas mixture, of which H2 accounts for 10%.   5. Display system (placed on the side of the glove box) Explosion-proof touch screen, placed on the side of the box.   6. Water analyzer, (imported from abroad) Brand: Britain MICHELL / (placed in the explosion-proof cabinet) Non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detected value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10 ℃ -50 ℃   7. Oxygen analyzer, (imported from abroad) brand: the United States Avcray (placed in the explosion-proof cabinet) Non-domestic or domestic assembly, third-party data to ensure credibility. 1)Measuring range can be set: 0-1000ppm 2)Environment: -10℃ -50℃ 3)Accuracy: ±1% ppm 4)Installation position: Oxygen sensor is installed on the box, regardless of the gas cycle or not, the oxygen sensor uninterruptedly detects the atmosphere inside the box and displays the oxygen content inside the glove box. 5)Sensor: electrochemical material battery, its advantages are accurate zero point, small drift, avoid other battery material is easy to be corroded; low replacement cost (only replace the oxygen battery). 6)Display: The output of the analyzer is connected to PLC, the detected value is displayed on the touch screen, and the alarm value can be set. 7) Control: The user can select the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range.   8. Explosion-proof vacuum system The vacuum pump is a Bose explosion-proof vacuum pump, model DRV16, with a pumping speed of 16m³/h and an ultimate vacuum of 2x10-3 mbar. It can vacuum the transition chamber separately and realize separate control at any time.   9. Box automatic cleaning (placed in explosion-proof cabinet) 1. Automatic gas control plating plate; box gas automatic cleaning function user set cleaning time, and then touch the start button on the touch screen, the system will begin to clean the box, to the set time is automatically stopped. Increase the vacuum pump start and stop time control. 2. Automatic box cleaning function. Different nature of the gas environment replacement and misoperation into the water, oxygen and rapid automatic cleaning of the box. Box automatic clear valve to the box body piping integration to KF25 steel wire with steel tubes firmly connected to the external KF25 Pagoda connector.   10. Organic solvent adsorption system (HF adsorption device) In order to prevent the impact of organic solvents on the purification column, tandem 1 solvent column to the glove box system, can effectively remove the solvents volatilized out of the system at the same time ready to prevent the formation of hydrofluoric acid adsorbent material, the medium is mainly high-quality high-efficiency activated carbon and activated alumina. The filling quantity is 7KG, there is KF40 interface on the top and bottom of the column, which is convenient for material exchange, and users can change the material by themselves.   Equipment working conditions: (provided by the user) 1. Power supply: two-phase three-wire AC220V, power ≥ 1Kw; 2. Laboratory to have an independent ground: <3Ω, from the equipment to the ground connection is recommended to use ≥ 10mm2 flat copper wire; 3. Relative humidity: <75%; 4. Indoor no large amount of dust, no corrosive, flammable and explosive gases; 5. Inert gas: working gas requirements to provide 0.4-0.6mpa, mixed gas working pressure 0.01-0.05mpa; 6. During the installation and commissioning of the pressure reducing valve and gas demand side to provide; 7. Equipment footprint: length × width: 4000mm × 1000mm 8. Weighing requirements: ≤ 500kg / m ³   Main configurations and scope of supply No. Configuration Unit (of measure) Amount Manufacturer/Brand Remarks 1 Box Pcs 2 TMAXCN 304 Stainless steel thickness 3mm 2 Transition cabinet Sets 2 TMAXCN 304 Stainless steel (large and small compartments) 3 Control system Sets 1 Germany SIEMENS OMRON electronic devices, etc. Imported assembled 4 Circulation system (including purification and regeneration system) Sets 1 Germany BASF, the United States UOP purification materials, Germany Bauder valve Import assembly 5 Explosion-proof display system Sets 1 BT4 Ansheng explosion-proof 6 Gloves Pairs 2 United States Imported 7 Pipe connections Sets 1 France Legris Import 8 Pressure gauges Sets 2 Germany Wika Imported 9 PLC water analyzer Pcs 1 Michell, UK Import 10 PLC Oxygen Analyzer Pcs 1 Avcray USA Imported 11 Explosion-proof vacuum pump Pcs 1 Bowes Domestic 12 Oil Mist Filter Pcs 1 Bowes Domestic 13 Explosion Proof Foot Pedal Sets 1 Giant Leap Domestic 14 Pressure Sensor Sets 1 Explosion-proof Imported 15 HF Adsorption Column Sets 1 TMAXCN 304   Acceptance criteria Under the standard condition, i.e. 20-25℃ constant temperature, 65% relative humidity, 99.999% inert gas source, the oxygen index of circulating water in the empty box body reaches less than 1ppm.                     

Go To Page