Air Tightness Tester

Air Tightness Tester Air-leakage Test Machine

  • Model Number:

    TMAX-HF-8YQ
  • Compliance:

    CE Certified
  • Warranty:

    One year limited warranty and lifetime support
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days
Product Details


Air Tightness Tester Air-leakage Test Machine

1. This series supports leak test methods such as leak test, positive pressure test and negative pressure test. The range of leak test is - 85kpa ~ 800kpa.
2. The 7-inch touch screen is used as the human-machine interface, which can easily monitor the test results and set various parameters during the leakage test.
3. It has the alarm function of qualified / unqualified products, which can eliminate the possibility of manual misjudgment and false inspection.
4. It can accept the control of external sensor and switch button, and can control the external relay, solenoid valve and other executive components to realize the full automation of test.
5. With test data recording function, it can store 8000 test data for 24 hours
6. Testing units: kPa, PA, MPa, bar.
7. With optional external barcode scanning module, it can automatically read the current product information and upload the test data to the computer through RS485 for saving.


Specifications

Color

 Beige

Size

 310*440*330(mm)

Weight

 13kg

Power Supply

 AC 100-240V, 50HZ,

Power

50W

Test Gas Source

 0.4--0.8Mpa(Clean and Dry

Test Medium

 Compressed Air/Customer Specified Medium

Working Environment

 0-50℃,≤95% No Condensation

Test Port No.

 1/2/4

Pressure Methods

 Positive, Negative Pressure, Positive and Negative Pressure

Pressure Regulation Mode

 Manual

Regulation Precision of Pressure Adjust

 ±0.05%FS

Pressure Repetition Accuracy

 0.1%FS

Pressure Adjustment Range

 -85Kpa--+1600Kpa

Sensor Selection Range

 -85Kpa--+1600Kpa

Sensor Accuracy

 0.1%FS

Touch Screen

 7/10 " Color LCD

Languages

 Chinese, English, Japanese, German, Spanish, Russian (other languages customizable)

Programs' No.

 16/99 groups program

Judgment/Alarm

 Automatic Decision/Sound + Light Alarm Control

 I/O Port

 Input/output, 4 relay control functions (safety grating, solenoid valve and red and green warning light can be connected)

Parallel Communication(RS485)

 Input/OutputTest Data, Set Value, Receive External PLC Control Signal

Historical Records

It can store 100,000 test results and upload them to the computer via usb flash drive.


 