products categories
- Battery Production Equipment Line
- Battery Lab Pilot Equipment Line
- Lithium Battery Pack Assembly Line
- Solid State Battery Assembly Line
- Sodium Ion Battery Production Line
- Supercapacitor Assembly Line
- Lithium Ion Battery Recycling Plant
- Dry Electrode Preparation Solution
- Perovskite Based Solar Cell Lab Line
- Li ion Battery Materials
- Cathode Active Materials
- Anode Active Materials
- Customized Battery Electrode
- Coin Cell Parts
- Lithium Chip
- Cylindrical Cell Parts
- Battery Current Collectors
- Battery Conductive Materials
- Electrolyte
- Metal Mesh
- Battery Binder
- Separator and Tape
- Aluminum Laminate Film
- Nickel Strip
- Battery Tabs
- Graphene Materials
- Nickel Felt
- Titanium Fiber Felt
- Battery
- Battery Pack Machine & Compoments
- Battery Pack Compoments
- Turnkey Solutions Battery Pack Assembly Line
- Cell Sorter
- Battery Pack Spot Welder
- Laser Welder
- Battery Charging Discharging Tester
- Battery Pack Aging Machine
- Battery Pack Comprehensive Tester
- CCD Visual Inspector
- Battery Pape Sticking Machine
- BMS Testing Machine
- Al Wire Bonding Machine
- Lithium Battery Machine
- Battery Tester & Analyzer
- Battery Safety Tester
- Battery Material Tester
- Rolling Press Machine
- Spot Welding Machine
- Vacuum Mixer Machine
- Crimping/Disassembling Machine
- Vacuum Sealing Machine
- Electrolyte Filling
- Stacking/Winding Machine
- Electrode Cutter/Slitter
- Pouch Forming Machine
- NMP Solvent Treatment System
- Lithium Battery Production Plant
- Vacuum Glove Box
- Furnaces
- Coaters
- Hydraulic Press
- Ball Mill
- Planetary Centrifugal Mixer
- Laboratory Machine
- Metal Foam
contact us
- If you have questions, please contact us, all questions will be answered
- WhatsApp : +86 13003860308
- Email : David@tmaxcn.com
- Email : Davidtmaxcn@gmail.com
- Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
84V10A 60A Battery Pack Comprehensive Tester
Model Number:
TMAX-84V-10A60ADimension(L*W*H):
86 * 67 * 92cmNet Weight:
150kgCompliance:
CE CertifiedWarranty:
One years limited warranty with lifetime technical supportPlace of Origin:
ChinaMOQ:
1Payment:
L/C D/A D/P T/T Western UnionDelivery Time:
15 days
- WhatsApp : +86 13003860308
- Email : David@tmaxcn.com
- Email : Davidtmaxcn@gmail.com
- Wechat : 18659217588
Previous:
60A 120A 180A 300A 1-24/32 Series BMS Tester with CANNext:
120V 30A Regenerative Type Battery Pack Charge Discharge Aging Machine
84V10A 60A Battery Pack Comprehensive Tester
1、 Function introduction:
The functions of the test instrument are divided into two major parts, namely battery production test mode and calibration mode. Therefore, the equipment can be used as electronic load and comprehensive testing instrument.
The specific test items are: battery open circuit voltage, battery AC internal resistance, continuous charging current, continuous charging voltage, continuous discharge current, continuous discharge voltage, charging overcurrent protection current, discharge overcurrent protection current, short circuit protection time, overcurrent delay time, and voltage after test. The equipment adopts infrared scanning gun barcode input (SN) to start the test or automatically start the test when voltage is detected.
Scope of application: Lithium ion batteries are equipped with (CH+P+CH - P -), all series of power batteries.
2、 Test items:
1. Voltage: the test instrument tests the voltage twice, one is the no-load voltage, and the other is the voltage after all items are tested, especially after the short term protection, to ensure whether the battery is normal after the short term protection. Therefore, the two voltages are somewhat different, and the secondary voltage is smaller than the first.
2. Internal resistance: 1000 HZ AC internal resistance of the battery is tested,
3. Charging overcurrent protection current: first, confirm whether the battery has the automatic protection function after the charging current is too high. If the charging current is too high, the battery has no protection function, and it is easy to burn the protection circuit board in the battery. Therefore, it is critical to ensure whether the battery has the charging overcurrent protection current function. If not, choose the continuous charging current.
4. Continuous charging current: For the circuit board with no automatic protection function against excessive charging current, the current value of such battery is generally the same as that of the charger when charging.
5. Discharge overcurrent protection current: when the discharge current exceeds a certain value, automatic protection is generally available according to the specification parameters.
6. Continuous discharge current: refers to the discharge current of the battery during normal use. If there is a problem with the circuit board, it will not continue to discharge.
7. Short circuit protection time. If the internal resistance value of the whole circuit is too large during the short circuit, the short circuit time will be too long. Therefore, pay attention to analyze the causes when the short circuit is too long.
3、Technical parameters:
Voltage range
0-84V
Accuracy
1mV
Internal resistance range
0-2000 mOhm
Accuracy
0.01 mOhm
Charging current
(0-10A) or (0-30A)
Accuracy
0.1A
The discharge current
(0-60A) is at the highest voltage, the sustainable discharge current is 60A, and the accuracy is 0.1A (customized if customers have higher current requirements).
Short circuit time
0-2000uS
accuracy
1uS
Size
86 * 67 * 92cm
Weight
150 KG
4、 Standard accessories:
1 TG6000 host, 1 power cable, 1 serial port cable, 1 manual
84V10A 60A Battery Pack Comprehensive Tester
1、 Function introduction:
The functions of the test instrument are divided into two major parts, namely battery production test mode and calibration mode. Therefore, the equipment can be used as electronic load and comprehensive testing instrument.
The specific test items are: battery open circuit voltage, battery AC internal resistance, continuous charging current, continuous charging voltage, continuous discharge current, continuous discharge voltage, charging overcurrent protection current, discharge overcurrent protection current, short circuit protection time, overcurrent delay time, and voltage after test. The equipment adopts infrared scanning gun barcode input (SN) to start the test or automatically start the test when voltage is detected.
Scope of application: Lithium ion batteries are equipped with (CH+P+CH - P -), all series of power batteries.
2、 Test items:
1. Voltage: the test instrument tests the voltage twice, one is the no-load voltage, and the other is the voltage after all items are tested, especially after the short term protection, to ensure whether the battery is normal after the short term protection. Therefore, the two voltages are somewhat different, and the secondary voltage is smaller than the first.
2. Internal resistance: 1000 HZ AC internal resistance of the battery is tested,
3. Charging overcurrent protection current: first, confirm whether the battery has the automatic protection function after the charging current is too high. If the charging current is too high, the battery has no protection function, and it is easy to burn the protection circuit board in the battery. Therefore, it is critical to ensure whether the battery has the charging overcurrent protection current function. If not, choose the continuous charging current.
4. Continuous charging current: For the circuit board with no automatic protection function against excessive charging current, the current value of such battery is generally the same as that of the charger when charging.
5. Discharge overcurrent protection current: when the discharge current exceeds a certain value, automatic protection is generally available according to the specification parameters.
6. Continuous discharge current: refers to the discharge current of the battery during normal use. If there is a problem with the circuit board, it will not continue to discharge.
7. Short circuit protection time. If the internal resistance value of the whole circuit is too large during the short circuit, the short circuit time will be too long. Therefore, pay attention to analyze the causes when the short circuit is too long.
3、Technical parameters:
Voltage range |
0-84V |
Accuracy |
1mV |
Internal resistance range |
0-2000 mOhm |
Accuracy |
0.01 mOhm |
Charging current |
(0-10A) or (0-30A) |
Accuracy |
0.1A |
The discharge current |
(0-60A) is at the highest voltage, the sustainable discharge current is 60A, and the accuracy is 0.1A (customized if customers have higher current requirements). |
||
Short circuit time |
0-2000uS |
accuracy |
1uS |
Size |
86 * 67 * 92cm |
||
Weight |
150 KG |
4、 Standard accessories: