products
5V 3A Battery Tester

5V 3A 512 Channel Power Pouch Cell Battery Tester

  • Model Number:

    TMAX-CTS-5V3A-512
  • Input Power:

    27KW
  • Dimension(L*W*H):

    L1600*W550*H1840mm
  • Compliance:

    CE Certified
  • Warranty:

    1 year
  • MOQ:

    1
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    25 days
Product Details

5V 3A 512 Channel Power Pouch Cell Battery Tester


1. Equipment structure:
Number of equipment channels: 512 channels for the whole machine
Overall dimensions: 160cm wide * 55cm deep * 184cm high
Customizable models: 5V-2A/5V-3A/5V6A
Applicable battery type: polymer battery, flexible battery
Chassis color: standard off white (customizable)
Fixture form: 65mm integrated snap polymer (customizable)
Support battery specification: pole piece ≤ 65mm
Working power supply: three-phase five wire AC380V+10%, 50Hz
Working power consumption: ≤ 9KW ≤ 14KW ≤ 27KW
Working environment: temperature 0~40 ℃, relative humidity ≤ 80%

Heat dissipation mode: natural air intake and upward exhaust.


2. Channel parameters:
Voltage measurement range: 0V~5V, resolution: 1mV
Battery voltage range: charging 0~4.5V; Discharge 4.5V~2V
Constant voltage range: 2.5V~4.5V
Voltage accuracy: ± (1 ‰ reading+1 ‰ full scale)
Current range: 20mA~2A; 30mA~3A   ; 60mA~6A 

Current accuracy: ± (1 ‰ reading+1 ‰ full scale)


3. Software functions:
Control mode: the computer connects the equipment to work, and the whole cabinet controls.
Communication mode: RS485, baud rate 57600
Process settings: Up to 32 work steps and 256 cycles can be set
Charging mode: constant current, constant voltage
Charging cut-off conditions: voltage, current, time, capacity.
Discharge mode: constant current
Discharge cut-off conditions: voltage, time, capacity.
Protection function: overvoltage, undervoltage, overcurrent, undercurrent, overcurrent, etc.
Time range: any setting within 0~30000 minutes
Time accuracy: ≤± 1 ‰
Sampling inspection cycle: ≤ 8S
Minimum data recording frequency: ≤ 8S
Battery sorting: by capacity, time, discharge platform, etc

Data processing: data, graph, etc.