products categories
- Battery Production Equipment Line
- Battery Lab Pilot Equipment Line
- Lithium Battery Pack Assembly Line
- Solid State Battery Assembly Line
- Sodium Ion Battery Production Line
- Supercapacitor Assembly Line
- Lithium Ion Battery Recycling Plant
- Dry Electrode Preparation Solution
- Perovskite Based Solar Cell Lab Line
- Li ion Battery Materials
- Cathode Active Materials
- Anode Active Materials
- Customized Battery Electrode
- Coin Cell Parts
- Lithium Chip
- Cylindrical Cell Parts
- Battery Current Collectors
- Battery Conductive Materials
- Electrolyte
- Metal Mesh
- Battery Binder
- Separator and Tape
- Aluminum Laminate Film
- Nickel Strip
- Battery Tabs
- Graphene Materials
- Nickel Felt
- Titanium Fiber Felt
- Battery
- Battery Pack Machine & Compoments
- Battery Pack Compoments
- Turnkey Solutions Battery Pack Assembly Line
- Cell Sorter
- Battery Pack Spot Welder
- Laser Welder
- Battery Charging Discharging Tester
- Battery Pack Aging Machine
- Battery Pack Comprehensive Tester
- CCD Visual Inspector
- Battery Pape Sticking Machine
- BMS Testing Machine
- Al Wire Bonding Machine
- Lithium Battery Machine
- Battery Tester & Analyzer
- Battery Safety Tester
- Battery Material Tester
- Rolling Press Machine
- Spot Welding Machine
- Vacuum Mixer Machine
- Crimping/Disassembling Machine
- Vacuum Sealing Machine
- Electrolyte Filling
- Stacking/Winding Machine
- Electrode Cutter/Slitter
- Pouch Forming Machine
- NMP Solvent Treatment System
- Lithium Battery Production Plant
- Vacuum Glove Box
- Furnaces
- Coaters
- Hydraulic Press
- Ball Mill
- Planetary Centrifugal Mixer
- Laboratory Machine
- Metal Foam
contact us
- If you have questions, please contact us, all questions will be answered
- WhatsApp : +86 13003860308
- Email : David@tmaxcn.com
- Email : Davidtmaxcn@gmail.com
- Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
Small 1100C 2 in 1 Box Muffle & Tube Dual-use Furnace Can be Used in Glove Box
Model Number:
TMAX-KTL1100-SCompliance:
CE CertifiedWarranty:
Two years limited warranty with lifetime technical supportPayment:
L/C D/A D/P T/T Western UnionDelivery Time:
5 days
- WhatsApp : +86 13003860308
- Email : David@tmaxcn.com
- Email : Davidtmaxcn@gmail.com
- Wechat : 18659217588
Previous:
Small 1000C Electric Box Muffle FurnaceNext:
1200C degree Laboratory Heating Electric Muffle Box Furnace
Small 1100C 2 in 1 Box Muffle & Tube Dual-use Furnace Can be Used in Glove Box
KTL1100-S is a small mixed tube / box furnace. The size of the furnace is 100 × 100 × 100mm. As a simple box furnace, the sample can be heat-treated in an air environment. This equipment is equipped with quartz tube and stainless steel sealing flange, which can heat-treat samples under vacuum or atmosphere protection. The maximum temperature of the equipment can reach 1100 ℃, and the power is only 1.2KW. In addition, the device is small in size and can be put into a glove box for operation.
Main technical parameters
Model |
KTL1100-S |
Power |
1200W |
Chamber size(mm) |
100X100X100(LXWXH) 1L |
Tube size |
OD50*180mm, 350ml |
Dimension |
500X250X410mm(LXWXH) |
Main feature |
Box-type tubular dual-use. Small size, light weight, low power, can be used for operation in glove box and fume hood. The highest temperature can reach 1100 ℃. Open the door on the side for easy operation. Plug the furnace plug as box furnace & Insert tube as tube furnace |
Supply voltage |
220V |
Phase |
single phase |
Heating element |
Sweden Kanthal A1 imported resistance wire (the resistance wire can be guaranteed for 2 years) |
Control mode |
30-step program temperature control 1. The temperature control of the 30-segment program can only be adjusted by PID. 2. With over-temperature protection Broken-couple protection When the over-temperature or even-coupled circuit is broken, the heating circuit of the electric furnace is automatically cut off. (When the temperature of the electric furnace exceeds 1120 degrees or the thermocouple burns out, the AC relay on the main circuit will be automatically disconnected, the main circuit is disconnected, the ON lamp on the panel is off, the OFF lamp is on, and the electric furnace is limited to protect). 3. With 485 communication interface (standard configuration when software is selected) 4. With power-off protection function, that is, when the furnace is started after power-off, the program will not start from the starting temperature, but will start to rise from the power off. 5. The instrument has the function of temperature self-tuning.
|
control mode |
Intelligent PID |
over-temperature protection |
Yes |
overcurrent protection |
Yes |
Broken pair protection and display |
Yes |
Furnace material |
1. High-quality high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration. 2. Formed using Japanese technology. 3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal engineering technology in Japan, and the thermal field is simulated by the thermal engineering software. |
control accuracy |
±1 ℃ |
Max. temp |
1050 ℃ |
Rated temp |
1000 ℃ |
Thermocouple Type |
K |
silicon controlled |
TRIAC |
surface temp |
≤45℃ |
Warranty |
One year warranty and lifetime technical support. Special note: Consumable parts such as heating elements, sample crucibles, etc. are not covered by the warranty. Damage caused by the use of corrosive gases is not covered by the warranty. |
Precautions |
1. For safety, please put the stove in a ventilated place. 2. In order to increase the service life of the furnace, we recommend that the heating rate should not exceed 10 ℃ / min. The cooling rate does not exceed 5 ° C / min. 3. The furnace has no vacuum tightness, and it is forbidden to pass toxic or explosive gas. 4. It is forbidden to put the materials directly on the brick at the bottom of the furnace. 5. When heating, the materials and crucible should not touch the heating element and thermocouple. 6. When not used for a long time, please use the oven again. |