products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13174506016
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
products
vacuum Glove Box

Battery small vacuum glove box for lithium ion batteries lab research

  • Model Number:

    TMAX-VGB-4
  • Dimension(L*W*H):

    3115 x 830 x 1830mm
  • Compliance:

    CE Certified
  • Warranty:

    One year limited warranty with lifetime support
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days
Product Details

Battery small vacuum glove box for lithium ion batteries lab research



Working Voltage

220V AC, 50/60Hz, Single Phase

Max. Power Consumption

3KW

Glove Box Chamber

·         Case Material: Stainless Steel 304

·         Dimensions: 2400mm(L) x 800mm(W) x 930mm(H)

·         12mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner


Chamber Condition

·         Water concentration: <1 ppm (20°C, 1 atm)

·         Oxygen concentration: <1 ppm (20°C, 1 atm)

Leak rate

<0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)


Air-lock Chamber

·         Antechamber Dimensions: 385mm(Dia.) x 588mm(L)

·         Small Chamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)

·         Max. vacuum level: 100 Pa


Working Gas

·         Operating gas: Inert gas such as N2, Ar, He

·         Regenerating gas: Mixture of H2 (10%) and Operating gas 

o    For purification system with only water adsorbing function, Regenerating gas will be the same as Operating gas


Gas Purification System

·         Automated Regeneration Process

·         Automated water and oxygen removal

·         Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials

·         Moisture removal capacity: 1.5KG

·         Oxygen removal capacity: 180L


Filter System

·         Organic Solvent Filter System filled with replaceable activated carbon

·         Built in HEPA filter can eliminate particle size > 0.3μm

Control system

·         Siemens PLC control system with 6" touch screen display

o    Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm

o    Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm

o    Pressure: -2500 to 2500 Pa with an accuracy of 1 Pa


Pump

·         England EDWARDS pump is included for faster vacuum and removing moisture

·         Vacuum rate: 8.4 - 12 m^3/hr

Blower

Flow Rate: 90m³/h

Purification Pipeline

304 Stainless Steel, KF40 Port

Gloves

A pair of NORTH butyl glove is included to provide better protection against toxic materials

Lighting

Built in fluorescent lamp


Slidable Shelf

·         Three slidable shelves are built 0n top of inside glove chamber with dimensions of 300mm x 250mm

·         300mm away from roof

Product Dimensions

3115mm(L) x 830mm(W) x 1830mm(H) (123" x 33" x 72")

Shipping Dimensions & Weight

Total 2 pallets

#1: 86"x41"x84"

#2: 86"x41"x83"

Total weight 1800 lb



Warranty

·         One Year limited warranty with lifetime support

·         Rusting and damage due to improper storage condition or maintenance is not covered by warranty

·         Gloves are consumable items and are not covered under warranty

Application Notes

·         The channel between the glove box chamber and the gas purification system must be unimpeded during the operation of gas purifying

·         Always check the joints, gloves, sealing elements, and pipelines for air-tightness before and during the operation

·         Corrosive gases are prohibited as they will damage the water sensor and oxygen sensor

·         The inlet and outlet of the Air-lock Chamber must not be opened at the same time to prevent contamination by the external gas

·         Coolant water outlet must remain switched on all the time

·         System check frequently to replace filters and solvent adsorbents for maintanence and maximum efficiency

Specifications of Standard Model of Purification Glove Box

No.

Model No.

Box Dimensions

Total Dimensions

Operating Sides

Numbers of Gloves

Options

1

GBP800S-2

1200*800*930mm

1915*830*1830mm

Single

2

Single or double purification columns

2

GBP1000S-4

1200*1000*930mm

1915*1060*1830mm

Single

4

Single or double purification columns

3

GBP1000D-4

1200*1000*930mm

1915*1060*1830mm

Double

4

Single or double purification columns

4

GBP1200S-2

1200*1200*930mm

1915*1260*1830mm

Single

2

Single or double purification columns

5

GBP1200D-4

1200*1200*930mm

1915*1260*1830mm

Double

4

Single or double purification columns

6

GBP800S-3

1500*800*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

7

GBP1000S-3

1500*1000*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

8

GBP1000D-6

1500*1000*930mm

2215*1060*1830mm

Double

6

Single or double purification columns

9

GBP1200S-3

1500*1200*930mm

2215*1260*1830mm

Single

3

Single or double purification columns

10

GBP1200D-6

1500*1200*930mm

2215*1260*1830mm

Double

6

Single or double purification columns

11

GBP800S-4

1900*800*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

12

GBP1000S-4

1900*1000*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

13

GBP1000D-8

1900*1000*930mm

2615*1060*1830mm

Double

8

Single or double purification columns

14

GBP1200S-4

1900*1200*930mm

2615*1260*1830mm

Single

4

Single or double purification columns

15

GBP1200D-8

1900*1200*930mm

2615*1260*1830mm

Double

8

Single or double purification columns

Notes
Cabinet water and oxygen content under the standard condition:  
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gases
a) Working Gas: N2
ArHe and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements

 
 

small glove box