products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13003860308
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
products
BMS Tester

24 String Protection Board Tester Charge Discharge Current 300A

  • Model Number:

    TMAX-BP8858
  • Type:

    Manual
  • Input Power:

    1600W
  • Compliance:

    CE Certified
  • Warranty:

    1 Year Limited Warranty With Lifetime Support
  • Place of Origin:

    China
  • Shipping Port:

    Xiamen
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days
Product Details


24 String Protection Board Tester Charge Discharge Current 300A


Functions
1. Short circuit protection test (refers to the microsecond level of real short circuit protection test).
2. Drop test (it means that the signal line of a section can be detected when it falls off or breaks).
3. Self power consumption test (refers to the true and accurate self power consumption of each section).
4. Equalizing current and voltage (can accurately grasp the equalizing current and voltage)
The above technology is the result of many years of experience and research and development of our engineers and technicians, which is different from other instruments that need to be upgraded frequently.


Introduction
1. A 1-24 series power battery protection board tester with high degree of automation, friendly English interface, fast test speed and high test precision. It has 13 performances of testing overcharge, overcharge recovery, over discharge, over discharge recovery, overcurrent (overcharge current and over discharge current), internal resistance, self consumption, short circuit protection, overcharge protection time, overcurrent protection time, over discharge protection time, equalizing current and equalizing voltage.
2. It can meet the test of lithium iron phosphate battery and cobalt acid battery protection board in the current market, and has the test gear switching function of iron battery and cobalt acid battery.
3. The instrument is required to be connected to a computer. The computer hardware configuration requires a general office computer. The system generally requires an XP system. The instrument and computer adopt an industrial standard 232 interface.


Technical parameter

1. Input power requirements: 180 ~ 240V, 50 / 60Hz, power: 1600W

2. The requirement for equipment access to power is 220V / 50Hz AC used in China, and the allowable fluctuation range is within 10%.

3. Charging and discharging voltage: 5000mv ~ 90000mv

4. When charging or discharging the equipment, it can be used to detect and set the voltage range.

5. Current accuracy: ± (0.1% FS + 0.1% RD)

6. When the equipment detects or sets the current, the error range is 0.1% of the full scale plus 0.1% of the reading error

7. Voltage accuracy: ± (0.1% FS + 0.1% RD)

8. When the equipment detects or sets the voltage, the error range is 0.1% of the full scale plus 0.1% of the reading error

9. Current resolution: 1mA

10. The minimum unit used by the equipment when detecting or setting current.

11. Voltage resolution: 1mV

12. The minimum unit used by the equipment when detecting or setting voltage.

13. Cycle: cycle times: 1 ~ 9999 times

14. By programming, the equipment can continuously cycle the indexes of the protection board.

15. Log tracking

16. It has log function, including operation records and abnormal records during the whole test process, which can be used for tracing the test process.

17. Data processing, man-machine interface

18. Test data can be exported into excel file and TXT text format.

19. Interface between equipment and upper computer: RS232

20. The interface between the equipment and the host computer adopts RS232 interface, which can ensure the stability and real-time of data acquisition.

21. Accuracy calibration / software calibration 22 external code scanning function

 

Test function

1.General performance test.

2. Charge discharge test, open circuit voltage, VCC voltage and on load voltage test, ID resistance, NTC resistance and on resistance test, single cell consumption current test and single cell equalization current test.

3. Single cell overcharge protection and over discharge protection test, charging over-current and discharge over-current protection test, simulated short circuit protection test and simulated over temperature protection test.1. Others: precharge test, MOSFET g-pole signal (BH signal) detection.

 

 Electrical performance parameters of main circuit

Project

Parameter description

Voltage

144000mV

Voltage resolution

1mV

Voltage accuracy

±0.1%

Chargedischarge

current

1A ~ 300A

Current resolution

1mA

Current accuracy

±0.1%

Other

The charging and discharging circuits are completely

separated


Electrical performance parameters of single string CELL

Project

Parameter description

Voltage output of each section

 1000mV ~ 5000mV

Voltageinputof each section

 1000mV ~ 5000mV

Voltage resolution

1mV

Voltage accuracy

±0.05%

Testequalizing current

 1000mA

Electrical performance parameters of power box (overcurrent test part)

Project

Parameter description

Controllable analog

current range

 1A -300A

Controllable analog

current accuracy

 

±0.1%

Maximumoutput

voltage

 

5000mV


Other technical parameters of equipment

Project

Parameter description

Measuring range of

consumed current

1 ~ 1000uA

Consumed current

resolution

0.1uA

Resistance

ID resistance0.1%/ NTC resistance0.1%internal impedance0-999mr

Protectiontime

Overcurrent protection time: 0-999ms; Short circuit


resolution:

protection time: 0-999us

1channelsignal

voltage output:

0~5000mV

Ad / DA digits

AD16bitDA:16bit

Discharge mode

CC pattern

32 analog cells

Input / output 1000~5000mV, voltage accuracy ±0.1%

Communication Rate

2-way SBS communication, communication rate10~100Kbps

Other

One circuit voltage sampling 0~5000mV accuracy:±0.1%

 

 

 

 

Protection function

Global protection parameters 

(including reverse connection protection, lower voltage limit protection, upper voltage limit protection and upper current limit protection), CC charging protection parameters (abnormal voltage trend protection, abnormal charging current fluctuation protection and abnormal voltage fluctuation protection), CC discharge protection parameters (including abnormal voltage trend protection, abnormal discharge current fluctuation protection and abnormal voltage fluctuation

protection)

 

 

Communication

The equipment interface adopts RS232 /  DB9 interface and 38400 communication rate interface, which can ensure the stability and real-time of data acquisition. All communication ports of the equipment are isolated and have lightning protection design.

Circuit structure

Modular structure, spare parts and spare parts can be

used for timely replacement and maintenance.

Equipment mechanism

Split cabinet structure

Safety level

Accord with EN60950GB4943 requirement

 

 

Noise

The noise is tested according to the method of iec62040-3, and the noise is less than 70dba

The sound level meter used shall meet the provisions of type I in iec804, and the accuracy shall be better

than ± 0.5dB.

Degreeof

protection

IP20

Cabinet color

Grayish white

Chassis color

Grayish white

lightning protection

Meet the 2-pole lightning protection requirements of gb17626

Cooling

Forced air cooling, with at least 20cm space reserved

between the air outlet and air inlet

Start pulse voltage

For  equipment  test,   the  maximum  allowable pulse voltage at the beginning of process execution is  (set


 

number of test strings * set monomer voltage) *

110%, t ≤ 500us;

 

Start pulse current

Equipment test: when the overcurrent test process is started, the maximum allowable pulse current is ≤ the upper limit of the set overcurrent protection value *

120%, t ≤ 1ms;

Wiring mode

Reliable spring crimping mode is adopted for flexible disassembly and replacement.

 

coating laminating machine