products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13003860308
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
products
Slliding Furnace

1200℃ Two Zone Sliding Tube Furnace

  • Model Number:

    TMAX-TL1200-1200
  • Compliance:

    CE Certified
  • Warranty:

    One year limited warranty with lifetime technical support
  • Shipping Port:

    Xiamen
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days
Product Details


1200℃ Two Zone Sliding Tube Furnace


This sliding split-tube furnace uses a resistance wire (Swedish Canthal A1) as the heating element, adopts a double-layer shell structure and a 30-stage program temperature control system, phase-shift triggering, thyristor control, and the furnace chamber uses alumina polycrystalline fiber It has the advantages of balanced temperature field, low surface temperature, fast rise and fall temperature rate, energy saving, etc. It is an ideal product for high-temperature atmosphere sintering, atmosphere reduction, CVD experiment, vacuum annealing in universities, scientific research institutes, and industrial and mining enterprises.


Specifications

Model

TL1200-1200-I

TL1200-1200-II

TL1200-1200-III

power

3.6KW

3.6KW

3.6KW

Furnace tube size (OD) (mm)

Dia 60(OD) X1500mm

Dia80ODX1500mm

Dia100ODX1500mm

Outline size

1700X490X600

1700X490X600

1700X490X600

supply voltage

220V

Phase number

Single phase

Heating element

Sweden Kanthal A1 imported resistance wire

temperature control

Yudian program temperature control instrument (standard)

1.30-stage program temperature control intelligent PID adjustment.

2. With over-temperature protection, the electric furnace heating circuit is automatically cut off when the temperature is over-temperature or broken, (when the electric furnace temperature exceeds 1200 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit is broken. On, the ON light on the panel is off, the OFF light is on, and the limited protection electric furnace).

3. With 485 communication interface (standard when purchasing software)

4. With power-off protection function, that is, when the power is turned on after the power is turned off, the program does not start from the starting temperature, but the furnace temperature rises from the time of power failure.

5. With the function of temperature self-tuning



If you want to get an imported temperature controller, you may have the following choices for replacement with extra fees.


Furnace material

1. High quality and high purity alumina polycrystalline fiber solidified furnace formed by vacuum suction filtration.

2. Formed with Japanese technology.

3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the optimal thermal technology in Japan, and the temperature field is simulated by the thermal software

control accuracy

+/- 1 ℃

trigger

Phase-shifting trigger

An electric appliance

Zhejiang CHINT

SCR

106/16E SEMIKRON Germany

Maximum temperature in the first and second temperature zones

1200 ℃

Rated temperature of the first and second temperature zones

1100 ℃

Length of heating section in the first temperature zone

205mm

Length of heating section in the second temperature zone

205mm

Length of constant temperature section in the first temperature zone

80-100mm

Length of constant temperature section in the second temperature zone

80-100mm

Temperature calibration (optional)

Regular temperature calibration of tubular furnace can keep the accuracy and uniformity of furnace temperature. You can choose a set of simple calibration tools in our company to assist you in this work. The complete calibration kit includes standard thermocouple, temperature calibrator and compensation wire.

heating rate

≤100 ℃/ Min

Thermocouple model

K type

Ambient surface temperature

≤45℃

Cover opening protection system

When the furnace cover is opened, the relay will automatically cut off the main power supply, effectively ensuring the safety of users.

Vacuum system

(optional)


1)Generally, the gas in the furnace tube can be pumped out by roughly vacuumizing:TW-1.5A single-stage pump would be fine

2) The double-stage vacuum pump can pump the vacuum degree of tube furnace tube to about 10Pa.

3)The VS-0.1 vacuum system can pump the vacuum degree in the tube furnace to 0.1Pa (with resistance vacuum meter display).

4)VS high vacuum system (composed of molecular and mechanical pump) can pump the vacuum degree in the tube furnace to 10-3 Pa.

5)Constant pressure pump (the system can control the pressure in the pipe within - 100.0KPa ~ 100.0KPa).

6) British (INFICON) capacitance vacuum gauge (measuring range: 3.8x10-5 -1125 Torr, it can detect various gases, including mixed gases, with accurate measurement, good repeatability, and optional anti-corrosion type: PCG554)

Gas supply system

(optional)

 

 Standard configuration

Item name

Quantity

Sliding tube furnace

1

Quartz tube

1

Stainless steel flange

1

Flange bracket

1

Stainless steel hook

1

Alumina plug

3

High temperature gloves

1

alumina crucible

1

K-type thermocouple

2

Com to USB interface (optional)

1

Instructions

1

Software (optional)

1

tube furnace